Comparative evaluation of efficacy and safety of ophthalmic viscosurgical devices in phacoemulsification [ISRCTN34957881]

被引:16
|
作者
Vajpayee R.B. [1 ]
Verma K. [1 ]
Sinha R. [1 ]
Titiyal J.S. [1 ]
Pandey R.M. [2 ]
Sharma N. [1 ]
机构
[1] Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Science, New Delhi
[2] Department of Biostatistics, All India Institute of Medical Science, New Delhi
关键词
ophthalmic viscosurgical device; phacoemulsification; corneal endothelium;
D O I
10.1186/1471-2415-5-17
中图分类号
学科分类号
摘要
Background: Various ophthalmic viscosurgical devices (OVD) are used to perform phacoemulsification and other intraocular surgeries. We performed a study to compare the efficacy and safety of three ophthalmic viscosurgical devices that are routinely used in phacoemulsification. Methods: Fifty-six patients of immature senile cataract with hard nucleus (grade 3 and 4) who underwent phacoemulsification were included. Depending upon the type of OVD, patients were randomly allocated into three groups; group 1 (n = 19), Viscoat® was used; group 2 (n = 19), Healon GV® was used; group 3 (n = 18), Healon 5® was used. Parameters evaluated were uncorrected and best corrected visual acuity, specular microscopy, intraocular pressure and pachymetry both preoperatively and postoperatively on day 1, 1 week, 1 month and 3 months and development of any complication both intraoperative and postoperative were also noted. Results: The mean increase in central corneal thickness was 15.17% (group 1); 17.26% (group 2) and 16.21% (group 3) on first postoperative day and was comparable in the three groups. The density of endothelial cells decreased postoperatively (day 1) by 12.54% (group 1), 13.76% (group 2) and 13.06% (group 3) and was comparable. The mean preoperative intraocular pressure in groups 1, 2 and 3 were 13.3 ± 2.0, 14.0 ± 2.2 and 13.2 ± 3.2 mmHg respectively, which changed to 16.0 ± 4.7, 12.2 ± 4.7 and 12.3 ± 4.8 respectively on first postoperative day and the change in intraocular pressure was significantly higher in group 1 (1 vs 2 & 1 vs 3; p = 0.02; oneway ANOVA). Conclusion: Viscoat® , Healon GV® and Healon 5® give comparable results in terms of efficacy and safety in performing phacoemulsification. © 2005 Vajpayee et al; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 50 条
  • [1] Pure phaco: phacoemulsification without ophthalmic viscosurgical devices
    Bardoloi, Narayan
    Sarkar, Sandip
    Pilania, Ashu
    Das, Himangshu
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (02): : 174 - 178
  • [2] In vitro behavior of ophthalmic viscosurgical devices during phacoemulsification
    Bissen-Miyajima, Hiroko
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (06): : 1026 - 1031
  • [3] Intraoperative evaluation of phacoemulsification cataract surgery with and without the use of ophthalmic viscosurgical devices
    Joshi, Rajesh Subhash
    Naik, Sanoja Rangnath
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2020, 27 (01) : 47 - 52
  • [4] Efficacy of Ophthalmic Viscosurgical Devices in Preventing Temperature Rise at the Corneal Endothelium during Phacoemulsification
    Suzuki, Hisaharu
    Igarashi, Tsutomu
    Shiwa, Toshihiko
    Takahashi, Hiroshi
    CURRENT EYE RESEARCH, 2016, 41 (12) : 1548 - 1552
  • [5] The safety and efficacy of phacoemulsification surgery in uncomplicated cataracts with and without an ophthalmic-viscosurgical-device
    Akmaz, Berkay
    Kilic, Deniz
    Duru, Necati
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 269 - 277
  • [6] Alteration of free radical development by ophthalmic viscosurgical devices in phacoemulsification
    Takahashi, Hiroshi
    Suzuki, Hisaharu
    Shiwa, Toshihiko
    Sakamoto, Atsuhiro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (09): : 1545 - 1548
  • [7] Novel Model Development for Preclinical Safety Evaluation of Ophthalmic Viscosurgical Devices
    Huang, Ling C.
    Gray, Brad
    Leang, Ronika
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [8] Oxidative tissue damage after phacoemulsification: Influence of ophthalmic viscosurgical devices
    Augustin, AJ
    Dick, HB
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02): : 424 - 427
  • [9] Retention time of different ophthalmic viscosurgical devices during phacoemulsification in rabbit ocular model: A comparative analysis
    Shalev, Daf
    Kleinmann, Guy
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 52 (06): : 639 - 643
  • [10] Residual amounts of ophthalmic viscosurgical devices on the corneal endothelium following phacoemulsification
    Yoshino, Mami
    Bissen-Miyajima, Hiroko
    Ohki, Shinichi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (01) : 62 - 64