Opinion Statement: Paravalvular leak (PVL) is a known complication of surgical and transcatheter valve replacement procedures. Patients most commonly present with congestive heart failure and/or hemolysis, and repeat surgical procedures to correct the PVL carries increased risk with reduced likelihood of success. As a result, percutaneous approaches to PVL closure have been developed, with a considerable emphasis on multimodality imaging for both diagnosis and procedural guidance in the cardiac catheterization laboratory. Large series' of percutaneous PVL closure have been recently published, with encouraging results with respect to both procedural success and clinical outcomes. In this paper, we provide a comprehensive review of imaging and procedural techniques for percutaneous PVL closure and present the data supporting this novel treatment strategy. © 2013 Springer Science+Business Media New York.
引用
收藏
页码:565 / 574
页数:9
相关论文
共 25 条
[1]  
Dunning J., Gao H., Chambers J., Moat N., Murphy G., Pagano D., Et al., Aortic valve surgery: Marked increases in volume and significant decreases in mechanical valve use - An analysis of 41,227 patients over 5 years from the society for cardiothoracic surgery in great britain and ireland national database, The Journal of Thoracic and Cardiovascular Surgery, 142, pp. 776-782, (2011)
[2]  
Gammie J.S., Sheng S., Griffith B.P., Peterson E.D., Rankin J.S., O'Brien S.M., Et al., Trends in mitral valve surgery in the united states: Results from the society of thoracic surgeons adult cardiac surgery database, The Annals of Thoracic Surgery, 87, pp. 1431-1437, (2009)
[3]  
Jindani A., Neville E.M., Venn G., Williams B.T., Paraprosthetic leak: A complication of cardiac valve replacement, The Journal of Cardiovascular Surgery., 32, pp. 503-508, (1991)
[4]  
Hammermeister K., Sethi G.K., Henderson W.G., Grover F.L., Oprian C., Rahimtoola S.H., Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: Final report of the veterans affairs randomized trial, Journal of the American College of Cardiology., 36, pp. 1152-1158, (2000)
[5]  
Ionescu A., Fraser A.G., Butchart E.G., Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: A prospective study using transoesophageal echocardiography, Heart, 89, pp. 1316-1321, (2003)
[6]  
Rodes-Cabau J., Transcatheter aortic valve implantation: Current and future approaches. Nature reviews, Cardiology, 9, pp. 15-29, (2012)
[7]  
Jilaihawi H., Kashif M., Fontana G., Furugen A., Shiota T., Friede G., Makhija R., Doctor N., Leon M.B., Makkar R.R., Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation, Journal of the American College of Cardiology, 59, pp. 1275-1286, (2012)
[8]  
Genoni M., Franzen D., Vogt P., Seifert B., Jenni R., Kunzli A., Niederhauser U., Turina M., Paravalvular leakage after mitral valve replacement: Improved long-term survival with aggressive surgery?, European Journal of Cardio-thoracic Surgery: Official Journal of the European Association for Cardio-thoracic Surgery, 17, pp. 14-19, (2000)
[9]  
De Cicco G., Russo C., Moreo A., Beghi C., Fucci C., Gerometta P., Lorusso R., Mitral valve periprosthetic leakage: Anatomical observations in 135 patients from a multicentre study, European Journal of Cardio-thoracic Surgery: Official Journal of the European Association for Cardio-thoracic Surgery, 30, pp. 887-891, (2006)
[10]  
Echevarria J.R., Bernal J.M., Rabasa J.M., Morales D., Revilla Y., Revuelta J.M., Reoperation for bioprosthetic valve dysfunction. A decade of clinical experience European journal of cardio-thoracic surgery, Official Journal of the European Association for Cardio-thoracic Surgery, 5, pp. 523-526, (1991)