A novel multiplex PCR method for the detection of virulence-associated genes of Escherichia coli O157:H7 in food

被引:0
|
作者
Vo Van Giau
Thuy Trang Nguyen
Thi Kim Oanh Nguyen
Thi Thuy Hang Le
Tien Dung Nguyen
机构
[1] Ho Chi Minh City University of Food Industry (HUFI),Deparment of Faculty of Food Technology
[2] Gachon University,Gachon Medical Research Institute
[3] University of Medicine and Pharmacy,Faculty of Pharmacy
[4] National Agro- Forestry- Fisheries Quality Assurance Department Branch 4 (NAFIQAD 4),Laboratory of Microbiology
来源
3 Biotech | 2016年 / 6卷
关键词
Multiplex PCR; Validation; O157:H7; stx1 and stx2;
D O I
暂无
中图分类号
学科分类号
摘要
Shiga toxin-producing Escherichia coli O157:H7 (E. coli O157:H7) strains are foodborne infectious agents that cause a number of life-threatening diseases, including hemorrhagic colitis (HC) and hemolytic uremic syndrome (HUS). Shiga toxin 1 (stx1), shiga toxin 2 (stx2), or a combination of both are responsible for most clinical symptoms of these diseases. Hence, various diagnostic methods have been developed so far to detect shiga toxins such as cell culture, ELISA, Rapid Latex Agglutination (RPLA) and hybridization, but due to high costs and labor time in addition to low sensitivity, they have not received much attention. The aim of this study was to develop a complete, rapid and reliable multiplex PCR (mPCR) method by using two pairs of specific primers to detect either the stx1 or the stx2 gene confirms the presence of E.coli O157:H7. The study results show that stx1F/stx1R primers are specific for stx1 and primers stx2F/stx2R are specific for stx2 genes in E. coli O157:H7. The mPCR method with two pairs of primers for amplifying the stx1, stx2 target genes to detect E. coli O157:H7 in food has been set up successfully. Complete method performed well in both types of food matrices with a detection limit of 3 CFU/25 g or mL of food samples. Tests on 180 food samples have shown a specificity value of 93.75 % (95 % confidence interval [CI], 82.83–100), a sensitivity of 100 % (95 % CI, 83.79–99.85 %), and an accuracy of 96.66 % (CI 95 %, 83.41–99.91 %). Interestingly, results indicate that the mPCR performed as well as the traditional culture methods and can reduce the diagnosis time to 2 days. Finally, complete mPCR method was applied to natural samples covering a wide variety of food types proving that the mPCR method was a rapid and reliable screening method for detection of E. coli O157:H7 in food and environmental samples.
引用
收藏
相关论文
共 50 条
  • [1] A novel multiplex PCR method for the detection of virulence-associated genes of Escherichia coli O157:H7 in food
    Vo Van Giau
    Thuy Trang Nguyen
    Thi Kim Oanh Nguyen
    Thi Thuy Hang Le
    Tien Dung Nguyen
    3 BIOTECH, 2015, 6 : 1 - 8
  • [2] A multiplex PCR procedure for the detection of six major virulence genes in Escherichia coli O157:H7
    Bai, Jianfa
    Shi, Xiaorong
    Nagaraja, T. G.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2010, 82 (01) : 85 - 89
  • [3] Multiplex PCR for detection of Escherichia coli O157:H7 in foods
    Vidova, Barbora
    Tothova, Eva
    Blahut, L'uboslav
    Horvathova, Viera
    Godany, Andrej
    BIOLOGIA, 2011, 66 (03) : 401 - 405
  • [4] Multiplex PCR for detection of Escherichia coli O157:H7 in foods
    Barbora Vidová
    Eva Tóthová
    Ľuboslav Blahut
    Viera Horváthová
    Andrej Godány
    Biologia, 2011, 66 : 401 - 405
  • [5] Detection of Escherichia coli O157:H7 in ground beef using immunomagnetic separation and multiplex PCR
    Sarimehmetoglu, Belgin
    Aksoy, Mihriban Hatun
    Ayaz, Naim Deniz
    Ayaz, Yidiz
    Kuplulu, Ozlem
    Kaplan, Yusuf Ziya
    FOOD CONTROL, 2009, 20 (04) : 357 - 361
  • [6] Molecular Detection and Characterization of Escherichia coli O157:H7 and O111 Associated with Milk Samples by Multiplex PCR
    Alwathnani, Hend A.
    Hessain, Ashgan M.
    JOURNAL OF PURE AND APPLIED MICROBIOLOGY, 2013, 7 : 447 - 451
  • [7] Simultaneous detection of Escherichia coli O157:H7, Staphylococcus aureus and Salmonella by multiplex PCR in milk
    Wei, Caijiao
    Zhong, Junliang
    Hu, Ting
    Zhao, Xihong
    3 BIOTECH, 2018, 8
  • [8] Simultaneous detection of Escherichia coli O157:H7, Staphylococcus aureus and Salmonella by multiplex PCR in milk
    Caijiao Wei
    Junliang Zhong
    Ting Hu
    Xihong Zhao
    3 Biotech, 2018, 8
  • [9] Application of multiplex PCR assay based on uidR and fliCH7 genes for detection of Escherichia coli O157:H7 in milk
    Kumar, Ashwani
    Grover, Sunita
    Batish, Virender Kumar
    JOURNAL OF GENERAL AND APPLIED MICROBIOLOGY, 2013, 59 (01) : 11 - 19
  • [10] Development of PCR assays for detection of Escherichia coli O157:H7 in meat products
    Gordillo, Ruben
    Cordoba, Juan J.
    Andrade, Maria J.
    Isabel Luque, M.
    Rodriguez, Mar
    MEAT SCIENCE, 2011, 88 (04) : 767 - 773