Automatic detection of the electrocardiogram T-wave end

被引:0
作者
I. K. Daskalov
I. I. Christov
机构
[1] Bulgarian Academy of Sciences,Centre of Biomedical Engineering
来源
Medical & Biological Engineering & Computing | 1999年 / 37卷
关键词
Electrocardiogram; T-wave end detection; Automatic detection algorithm; Signal processing;
D O I
暂无
中图分类号
学科分类号
摘要
Various methods for automatic electrocardiogram T-wave detection and Q-T interval assessment have been developed. Most of them use threshold level corrsing. Comparisons with observer detection were performed due to the lack of objective measurement methods. This study followed the same approach. Observer assessments were performed on 43 various T-wave shapes recorded: (i) with 100 mms−1 equivalent paper speed and 0.5mVcm−1 sensitivity; and (ii) with 160 mms−1 paper speed and vertical scaling ranging from 0.07 to 0.02 m Vcm−1, depending on the T-wave amplitude. An automatic detection algorithm was developed by adequate selection of the T-end search interval, improved T-wave peak detection and computation of the angle between two 10ms long adjacent segments along the search interval. The algorithm avoids the use of baseline crossin direct signal differentiation. It performs well in cases of biphasic and/or complex T-wave shapes. Mean differences with respect to observer data are 13.5 ms for the higher gain/speed records and 14.7 ms for the lower gain/speed records. The algorithm was tested with 254 various T-wave shapes. Comparisons with two other algorithms are presented. The lack of a ‘gold standard’ for the T-end detection, especially if small waves occur around it, impeded adequate interobserver assessment and evaluation of automatic methods. It is speculated that a simultaneous presentation of normal and high-gain records might turn more attention to this problem. Automatic detection methods are in fact faced with ‘high-gain’ data, as high-resolution analogue-to-digital conversion, is already widely used.
引用
收藏
页码:348 / 353
页数:5
相关论文
共 61 条
[1]  
Ahnve S.(1978)The relationship between QT interval and primary ventricular fibrillation in acute myocardial infarction Acta Med. Scand. 204 17-19
[2]  
Lundman T.(1994)QT dispersion and sudden death in chronic heart failure Lancet 343 327-329
[3]  
Shoaleh-Var M.(1988)Importance of lead selection in QT interval measurement Am. J. Cardiol. 61 83-87
[4]  
Barr C. S.(1990)QT dispersion: an indication of arrhythmia risk in patients with long QT intervals Brit. Heart J. 63 342-344
[5]  
Naas A.(1994)Time for yet another QT correction algorithm? Bazett and beyond J. Am. Coll. Cardiol. 23 1554-1556
[6]  
Freeman M.(1990)New algorithm for QT interval analysis in 24-hour Holter ECG: performance and applications Med. Biol. Eng. Comput. 28 67-73
[7]  
Lang C. C.(1996)QT interval and dispersion in primary autonomic failure Heart 75 498-501
[8]  
Struthers A. D.(1995)Comparison of automatic QT measurement techniques in the normal 12 lead electrocardiogram Br. Heart. J. 74 84-89
[9]  
Cowan J. C.(1989)Electrocardiographic quantitation of ventricular repolarization Circulation 80 1301-1308
[10]  
Yasoff K.(1996)Diurnal pattern of QTc interval: how long is prolonged? Possible relation to circadian triggers of cardiovascular events J. Am. Coll. Cardiol. 27 76-83