Solid phase extraction and preconcentration of Cu(II), Pb(II), and Ni(II) in environmental samples on chemically modified Amberlite XAD-4 with a proper Schiff base

被引:0
作者
Berrin Topuz
Mustafa Macit
机构
[1] Ondokuz Mayıs University,Department of Chemistry, Faculty of Art and Science
来源
Environmental Monitoring and Assessment | 2011年 / 173卷
关键词
Solid phase extraction; -bis(salicylidene)cyclohexanediamine (SCHD); Amberlite XAD-4; Schiff’s base; Preconcentration; FAAS;
D O I
暂无
中图分类号
学科分类号
摘要
A new chelating resin, Amberlite XAD-4 loaded with N,N-bis(salicylidene)cyclohexanediamine (SCHD), was synthesized and characterized. The resin Amberlite XAD-4-SCHD was used for selective separation, preconcentration, and determination of Cu(II), Pb(II), and Ni(II) ions in water samples by flame atomic absorption spectrometry (FAAS). Effects of pH, concentration, and volume of elution solution; flow rate of elution; and sample solution, sample volume, and interfering ions for the recovery of the analytes were investigated. These metal ions can be desorbed with 0.5-M HNO3 (recovery, 98%–101%). The sorption capacity was found between 1.38×10 − 1 and 3.58×10 − 1 mmol/g. In order to evaluate the accuracy of the proposed procedure, the certified reference materials, BCR-032 (Moroccan phosphate rock) and BCR-715 (industrial effluent wastewater), were analyzed. The detection limits of the method were found to be 0.11, 1.91, and 0.43 μg/L for Cu(II), Pb(II), and Ni(II), respectively. The method was applied to the extraction and the recovery of copper, lead, and nickel in wastewater and other water samples.
引用
收藏
页码:709 / 722
页数:13
相关论文
共 144 条
[1]  
Absalan G(2004)Optimizing the immobilized dithizone on surfactant-coated alumina as a new sorbent for determination of silver Separation and Purification Technology 38 209-214
[2]  
Goudi AA(2003)Gallium trace on-line preconcentration/separation and determination using a polyurethane foam mini-column and flame atomic absorption spectrometry. Application in aluminum alloys, natural waters and urine Talanta 60 929-936
[3]  
Anthemidis AN(2006)Determination of lead and nickel in environmental samples by flame atomic absorption spectrometry after column solid-phase extraction on Ambersorb-572 with EDTA Journal of Hazardous Materials B129 130-136
[4]  
Zachariadis GA(2009)On-line preconcentration of copper as its pyrocatechol violet complex on Chromosorb 105 for flame atomic absorption spectrometric determinations Journal of Hazardous Materials 163 1298-1302
[5]  
Stratis JA(2005)Immobilized salen ( Analytica Chimica Acta 539 69-75
[6]  
Baytak S(2007)-bis (salicylidene)ethylenediamine) as a complexing agent for on-line sorbent extraction/preconcentration and flow injection–flame atomic absorption spectrometry Journal of Hazardous Materials 149 331-337
[7]  
Türker AR(2003)Solid-phase extraction of Fe(III), Pb(II) and Cr(III) in environmental samples on Amberlite XAD-7 and their determinations by flame atomic absorption spectrometry Journal of Trace and Microprobe Techniques 21 351-361
[8]  
Buke B(2007)Trace heavy metal levels in street dust samples from Yozgat city center, Turkey Journal of Hazardous Materials 149 166-173
[9]  
Divrikli U(2007)The use of Journal of Hazardous Materials 146 347-355
[10]  
Soylak M(2009) immobilized on Amberlite XAD-4 as a new biosorbent in trace metal determination Journal of Hazardous Materials 162 292-299