MR imaging and proton spectroscopy of the breast: How to select the images useful to convey the diagnostic message

被引:10
作者
Fausto A. [1 ]
Magaldi A. [1 ]
Babaei Paskeh B. [1 ]
Menicagli L. [1 ]
Lupo E.N. [1 ]
Sardanelli F. [1 ]
机构
[1] Università degli Studi di Milano, Dipartimento di Scienze Medico-Chirurgische, IRCCS Policlinico San Donato, San Donato Milanese, Milano I-20097
关键词
Breast; Magnetic resonance (MR) imaging; Magnetic resonance (MR) spectroscopy;
D O I
10.1007/s11547-007-0193-x
中图分类号
学科分类号
摘要
Purpose. The purpose of this study was to propose a short way to summarise a breast magnetic resonance (MR) examination including a precontrast and contrast-enhanced dynamic study and proton spectroscopy (1H-MRS) in order to convey the diagnostic message. Materials and methods. At the Department of Radiology of the Policlinico San Donato (University of Milan), breast MR is routinely performed at 1.5 T as follows: 36-slice axial 2D short-time inversion-recovery (STIR) sequence; 128-partition 3D gradient-echo coronal sequence (1-mm3 siotropic voxel) before and after rapid automatic intravenous injection of 0.1 mmol/kg of Gd-DOTA (one precontrast and four postcontrast phases). Postprocessing includes temporal subtraction (postcontrast minus precontrast), maximum intensity projections (MIPs), percent enhancement-to-time curves for small regions of interest, and axial and/or sagittal multiplanar reconstructions. Single-voxel 1H-MRS is acquired to characterise focal lesions. Applying this protocol, more than 1,200 images are generated for each examination. We select only four MIPs of an early subtracted dynamic phase: one axial similar to craniocaudal x-ray mammographic views, one coronal, and two lateral similar to lateral 90° x-ray mammographic views. For each lesion described in the report, we select five items, including three images, one graph, and one table: STIR image, precontrast and subtracted postcontrast images (morphology), percent enhancement-to-time curves and a table of raw data generating the curves (dynamics). If 1H-MRS has been performed, we add other five items: two postprocessed spectra (metabolism) and three images localising the volume of interest. Only the selected items are printed on films and attached to the report. Results. The selected items range usually from four (no detected lesion) to 14 (one lesion, studied also with 1H-MRS), to 44 (five lesions, one of them studied also with 1H-MRS). The percentage of items presented with the report if compared with the total number of generated images is equal to 0.33% (4/1,200), 1.17% (14/1,200), and 2.83% (34/1,200), respectively. Conclusions. Breast MR imaging and 1H-MRS can be effectively summarised presenting only a minimal fraction of all generated images. © 2007 Springer-Verlag Italia.
引用
收藏
页码:1060 / 1068
页数:8
相关论文
共 12 条
[1]  
Sardanelli F., Iozzelli A., Fausto A., MR imaging of the breast: Indications, established technique, and new directions, Eur Radiol, 13, (2003)
[2]  
Baum F., Fischer U., Vosshenrich R., Grabbe E., Classification of hypervascularized lesions in CE MR imaging of the breast, Eur Radiol, 12, pp. 1087-1892, (2002)
[3]  
Katz-Brull R., Lavin P.T., Lenkinski R.E., Clinical utility of proton magnetic resonance spectroscopy in characterizing breast lesions, J Natl Cancer Inst, 9, pp. 1197-1203, (2002)
[4]  
Huang W., Fisher P.R., Dulaimy K., Tudorica L.A., O'Hea B., Button T.M., Detection of breast malignancy: Diagnostic MR protocol for improved specificity, Radiology, 232, pp. 585-591, (2004)
[5]  
Stanwell P., Gluch L., Clark D., Et al., Specificity of choline metabolites for in vivo diagnosis of breast cancer using 1H MRS at 1.5 T, Eur Radiol, 15, pp. 1037-1043, (2005)
[6]  
Bartella L., Morris E.A., Dershaw D.D., Et al., Proton MR spectroscopy with choline peak as malignancy marker improves positive predictive value for breast cancer diagnosis: Preliminary study, Radiology, 239, pp. 686-692, (2006)
[7]  
Mankovich N.J., Robertson D.R., Cheeseman A.M., Three-dimensional image display in medicine, J Digit Imaging, 3, pp. 69-80, (1990)
[8]  
Perrone L., Politi M., Foschi R., Postprocessing of digital images, Rays, 28, pp. 95-101, (2003)
[9]  
Duan S.Y., Zhang D.T., Lin Q.C., Wu Y.H., Clinical value of CT three-dimensional imaging in diagnosing gastrointestinal tract diseases, World J Gastroenterol, 12, pp. 2945-2948, (2006)
[10]  
Sardanelli F., Fausto A., Iozzelli A., Rescinito G., Calabrese M., Dynamic breast magnetic resonance imaging: Effect of changing the region of interest on early enhancement using 2D and 3D techniques, J Comput Assist Tomogr, 28, pp. 642-646, (2004)