Performance of independent dose calculation in helical tomotherapy: implementation of the MCSIM code

被引:0
|
作者
Eric Dzintars
Sotirios Stathakis
Panayiotis Mavroidis
Amir Sadeghi
Nikos Papanikolaou
机构
[1] University of Texas Health Science Center,Department of Radiological Sciences
[2] Karolinska Institute and Stockholm University,Department of Medical Radiation Physics
来源
Australasian Physical & Engineering Sciences in Medicine | 2012年 / 35卷
关键词
Independent dose calculation; Helical tomotherapy; Implementation; MCSIM code;
D O I
暂无
中图分类号
学科分类号
摘要
Currently, a software-based second check dose calculation for helical tomotherapy (HT) is not available. The goal of this study is to evaluate the dose calculation accuracy of the in-house software using EGS4/MCSIM Monte Carlo environment against the treatment planning system calculations. In-house software was used to convert HT treatment plan information into a non-helical format. The MCSIM dose calculation code was evaluated by comparing point dose calculations and dose profiles against those from the HT treatment plan. Fifteen patients, representing five treatment sites, were used in this comparison. Point dose calculations between the HT treatment planning system and the EGS4/MCSIM Monte Carlo environment had percent difference values below 5 % for the majority of this study. Vertical and horizontal planar profiles also had percent difference values below 5 % for the majority of this study. Down sampling was seen to improve speed without much loss of accuracy. EGS4/MCSIM Monte Carlo environment showed good agreement with point dose measurements, compared to the HT treatment plans. Vertical and horizontal profiles also showed good agreement. Significant time saving may be obtained by down-sampling beam projections. The dose calculation accuracy of the in-house software using the MCSIM code against the treatment planning system calculations was evaluated. By comparing point doses and dose profiles, the EGS4/MCSIM Monte Carlo environment was seen to provide an accurate independent dose calculation.
引用
收藏
页码:423 / 438
页数:15
相关论文
共 50 条
  • [21] Whole pelvic helical tomotherapy for locally advanced cervical cancer: technical implementation of IMRT with helical tomothearapy
    Chen-Hsi Hsieh
    Ming-Chow Wei
    Hsing-Yi Lee
    Sheng-Mou Hsiao
    Chien-An Chen
    Li-Ying Wang
    Yen-Ping Hsieh
    Tung-Hu Tsai
    Yu-Jen Chen
    Pei-Wei Shueng
    Radiation Oncology, 4
  • [22] Assessing the dose rate delivery of helical TomoTherapy prostate and head & neck treatments
    Kouris, P.
    Moutsatsos, A.
    Pappas, E. P.
    Beli, I
    Pantelakos, P.
    Karaiskos, P.
    Pantelis, E.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (01)
  • [23] TREATMENT PLANNING FOR PULSED REDUCED DOSE-RATE RADIOTHERAPY IN HELICAL TOMOTHERAPY
    Rong, Yi
    Paliwal, Bhudatt
    Howard, Steven P.
    Welsh, James
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (03): : 934 - 942
  • [24] VOXEL-BASED DOSE RECONSTRUCTION FOR TOTAL BODY IRRADIATION WITH HELICAL TOMOTHERAPY
    Chao, Ming
    Penagaricano, Jose
    Yan, Yulong
    Moros, Eduardo G.
    Corry, Peter
    Ratanatharathorn, Vaneerat
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1575 - 1583
  • [25] Craniospinal Irradiation Using Helical Tomotherapy: Evaluation of Acute Toxicity and Dose Distribution
    Sugie, C.
    Shibamoto, Y.
    Ayakawa, S.
    Mimura, M.
    Komai, K.
    Ishii, M.
    Miyamoto, A.
    Oda, K.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2011, 10 (02) : 187 - 195
  • [26] Impact of the Intra- and Inter-observer Variability in the Delineation of Parotid Glands on the Dose Calculation During Head and Neck Helical Tomotherapy
    Piotrowski, T.
    Gintowt, K.
    Jodda, A.
    Ryczkowski, A.
    Bandyk, W.
    Bak, B.
    Adamczyk, M.
    Skorska, M.
    Kazmierska, J.
    Malicki, J.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (04) : 467 - 474
  • [27] Study on dosimetric and radiation safety performance parameters of helical tomotherapy unit
    Ma Yongzhong
    Yang Bo
    Feng Zechen
    Wang Hongfang
    Wan Ling
    中华放射医学与防护杂志, 2015, 35 (01) : 62 - 68
  • [28] Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit
    Meeks, SL
    Harmon, JF
    Langen, KM
    Willoughby, TR
    Wagner, TH
    Kupelian, PA
    MEDICAL PHYSICS, 2005, 32 (08) : 2673 - 2681
  • [29] Feasibility of optimal vertex size and spacing for lattice radiotherapy implementation using helical tomotherapy
    Seol, Yunji
    Lee, Young Kyu
    Kim, Byeong Jin
    Choi, Kyu Hye
    Hong, Ji Hyun
    Park, Chan-beom
    Kim, Sun Hwa
    Park, Hyeong Wook
    Kim, Jung-Il
    Cheon, Wonjoong
    Kang, Young-nam
    Choi, Byung Ock
    FRONTIERS IN ONCOLOGY, 2025, 15
  • [30] A deep learning method for prediction of three-dimensional dose distribution of helical tomotherapy
    Liu, Zhiqiang
    Fan, Jiawei
    Li, Minghui
    Yan, Hui
    Hu, Zhihui
    Huang, Peng
    Tian, Yuan
    Miao, Junjie
    Dai, Jianrong
    MEDICAL PHYSICS, 2019, 46 (05) : 1972 - 1983