Computer-assisted revision of total knee arthroplasty

被引:0
作者
Aymard de Ladoucette
机构
[1] Clinique de l’Union,
来源
Knee Surgery, Sports Traumatology, Arthroscopy | 2009年 / 17卷
关键词
Computer assisted; Revision; Total knee arthroplasty; Joint line position;
D O I
暂无
中图分类号
学科分类号
摘要
Revision total knee prosthesis still remains a difficult procedure. Particularly, challenging is the restoration of the joint line to a normal position and the attainment of correct lower limb alignment and healthy bone support for the implants. Computer assistance improves accuracy during the implantation of primary total knees. The goal of this study was to evaluate the usefulness of computer assisted surgery (CAS) in total knee prosthesis revision. We revised 15 NKII total knee arthroplasties with the Navitrack system and compared the mechanical alignment and the joint line level on pre- and postoperative radiographs. After revision, the joint line position was restored. The knee with the revision prosthesis was aligned in the frontal plan with implants fixed perpendicularly to the mechanical axis. It is possible to correctly revise knee prosthesis with computer assistance only and without having to use a conventional ancillary. We had a permanent control of the joint line position and have performed the revision surgery following the same steps as in a primary implantation.
引用
收藏
页码:1166 / 1171
页数:5
相关论文
共 68 条
[1]  
Bathis H(2003)Alignment in total knee arthroplasty: a comparison of computer-assisted surgery with conventional technique J Bone Joint Surg Br 86 682-687
[2]  
Perlick L(2005)Computer navigation versus standard instrumentation for TKA: a single surgeon experience Clin Orthop Relat Res 440 162-169
[3]  
Tingart M(1987)Long term results after total condylar knee arthroplasty Clin Orthop Relat Res 216 151-158
[4]  
Luring C(1986)The influence of tibial-patellofemoral location on function of the knee in patients with the posterior stabilized condylar knee prosthesis J Bone Joint Surg Am 68 1035-1040
[5]  
Zurakowski D(2000)Revision total knee arthroplasty: current rationale and techniques for femoral component revision Clin Orthop Relat Res 380 116-132
[6]  
Grifka J(2003)Total knee prosthesis implantation with a non-image-based navigation system: rationale, technique, case-control comparative study with a conventional instrumented implantation Tech Orthop 18 160-166
[7]  
Bolognesi M(2002)Joint line position during revision total knee replacement Clin Orthop Relat Res 404 169-171
[8]  
Hofmann A(2006)Navigation in total knee arthroplasty. A multicenter study Int Orthop 30 536-540
[9]  
Ecker M(2006)Modular femoral offset stems facilitate joint line restoration in revision knee arthroplasty Clin Orthop Relat Res 446 93-98
[10]  
Lotke P(2006)Flexion and extension gap balancing in revision total knee arthroplasty Clin Orthop Relat Res 446 121-126