Functional MRI to quantify perfusion changes of a renal allograft after embolization of an arteriovenous fistula

被引:0
作者
Cecilia Liang
David J. Heister
Martina Guthoff
Gerd Grözinger
Petros Martirosian
Ferdinand Seith
机构
[1] University Hospital of Tuebingen,Diagnostic and Interventional Radiology, University Department of Radiology
[2] University Hospital of Tuebingen,Department of Nephrology
[3] University Hospital of Tuebingen,Section on Experimental Radiology, Diagnostic and Interventional Radiology, University Department of Radiology
来源
Journal of Nephrology | 2023年 / 36卷
关键词
Arterial spin labeling; Transplant kidney; Diffusion weighted imaging; Perfusion imaging; Arteriovenous fistula;
D O I
暂无
中图分类号
学科分类号
摘要
Acute allograft injury was observed in a 37-year-old woman within a few weeks after kidney transplantation. Neither renal ultrasound nor computerized tomography (CT) and magnetic resonance (MR) angiography revealed any anomaly. An MR protocol was then performed including arterial spin labeling and intravoxel incoherent motion diffusion weighted imaging. Both arterial spin labeling and the perfusion fraction in the diffusion weighted imaging showed decreased perfusion compared to reference values. The patient subsequently underwent angiography, where an arteriovenous fistula in the upper calix of the transplant kidney was detected and immediate embolization was performed. A second functional MR, performed one week later, demonstrated a 40% increase in organ perfusion. We conclude that functional MR with arterial spin labeling and intravoxel incoherent motion have the potential to provide complementary information of clinical value to conventional imaging for monitoring renal allografts.
引用
收藏
页码:1175 / 1180
页数:5
相关论文
共 47 条
  • [1] Mannon RB(2018)Delayed graft function: the AKI of kidney transplantation Nephron 140 94-98
  • [2] Ljimani A(2018)Functional MRI in transplanted kidneys Abdominal Radiol (New York) 43 2615-2624
  • [3] Wittsack H-J(2004)FAIR true-FISP perfusion imaging of the kidneys Magn Reson Med 51 353-361
  • [4] Lanzman RS(2021)Early detection of subclinical pathology in patients with stable kidney graft function by arterial spin labeling Eur Radiol 31 2687-2695
  • [5] Martirosian P(2016)Diffusion-Weighted imaging and diffusion tensor imaging detect delayed graft function and correlate with allograft fibrosis in patients early after kidney transplantation J Magn Reson Imaging 44 112-121
  • [6] Klose U(2022)Liquid embolics: a guide to currently available and pipeline products Dig Dis Interv 06 13-18
  • [7] Mader I(2018)Arterial spin labelling MRI to measure renal perfusion: a systematic review and statement paper Nephrol Dial Transplant 33 ii15-ii21
  • [8] Wang W(2018)Arterial spin-labeling improves detection of intracranial dural arteriovenous fistulas with MRI Am J Neuroradiol 39 669-677
  • [9] Yu Y(2016)Arterial spin labeling perfusion of the brain: emerging clinical applications Radiology 281 337-356
  • [10] Li X(2008)Arteriovenous shunt visualization in arteriovenous malformations with arterial spin-labeling MR imaging Am J Neuroradiol 29 681-687