Contribution of tissue composition and structure to mechanical response of articular cartilage under different loading geometries and strain rates

被引:0
作者
Petro Julkunen
Jukka S. Jurvelin
Hanna Isaksson
机构
[1] Kuopio University Hospital,Department of Clinical Neurophysiology
[2] Kuopio University Hospital,Department of Clinical Radiology
[3] University of Kuopio,Department of Physics
来源
Biomechanics and Modeling in Mechanobiology | 2010年 / 9卷
关键词
Articular cartilage; Fractional factorial design; Fibril-reinforced; Collagen; Fixed charge density; Finite element analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Mechanical function of articular cartilage in joints between articulating bones is dependent on the composition and structure of the tissue. The mechanical properties of articular cartilage are traditionally tested in compression using one of the three loading geometries, i.e., confined compression, unconfined compression or indentation. The aim of this study was to utilize a composition-based finite element model in combination with a fractional factorial design to determine the importance of different cartilage constituents in the mechanical response of the tissue, and to compare the importance of the tissue constituents with different loading geometries and loading rates. The evaluated parameters included water and collagen fraction as well as fixed charge density on cartilage surface and their slope over the tissue thickness. The thicknesses of superficial and middle zones, as based on the collagen orientation, were also included in the evaluated parameters. A three-level resolution V fractional factorial design was used. The model results showed that inhomogeneous composition plays only a minor role in indentation, though that role becomes more significant in confined compression and unconfined compression. In contrast, the collagen architecture and content had a more profound role in indentation than with two other loading geometries. These differences in the mechanical role of composition and structure between the loading geometries were emphasized at higher loading rates. These findings highlight how the results from mechanical tests of articular cartilage under different loading conditions are dependent upon tissue composition and structure.
引用
收藏
页码:237 / 245
页数:8
相关论文
共 190 条
[1]  
Alhadlaq HA(2004)Detecting structural changes in early experimental osteoarthritis of tibial cartilage by microscopic magnetic resonance imaging and polarised light microscopy Ann Rheum Dis 63 709-717
[2]  
Xia Y(2001)The accuracy and reliability of a novel handheld dynamic indentation probe for analysing articular cartilage Phys Med Biol 46 541-550
[3]  
Moody JB(1999)Nondestructive imaging of human cartilage glycosaminoglycan concentration by MRI Magn Reson Med 41 857-865
[4]  
Matyas JR(2007)Fourier transform infrared imaging and MR microscopy studies detect compositional and structural changes in cartilage in a rabbit model of osteoarthritis Anal Bioanal Chem 387 1601-1612
[5]  
Appleyard RC(2007)Indentation stiffness does not discriminate between normal and degraded articular cartilage Clin Biomech (Bristol, Avon) 22 843-848
[6]  
Swain MV(1995)Degenerative joint disease Clin Symp 47 1-32
[7]  
Khanna S(2002)Statistical methods in finite element analysis J Biomech 35 1155-1161
[8]  
Murrell GA(2001)In situ compressive stiffness, biochemical composition, and structural integrity of articular cartilage of the human knee joint Osteoarthritis Cartilage 9 582-592
[9]  
Bashir A(2001)Biochemical (and functional) imaging of articular cartilage Semin Musculoskelet Radiol 5 329-343
[10]  
Gray ML(2005)Zonal uniformity in mechanical properties of the chondrocyte pericellular matrix: micropipette aspiration of canine chondrons isolated by cartilage homogenization Ann Biomed Eng 33 1312-1318