Dried sewage sludge as an efficient adsorbent for pollutants: cationic methylene blue removal case study

被引:11
作者
Aoulad El Hadj Ali Y. [1 ]
Ahrouch M. [2 ,3 ]
Ait Lahcen A. [4 ]
Demba N’diaye A. [5 ]
El Yousfi F. [1 ]
Stitou M. [1 ]
机构
[1] Laboratoire de L’Eau, Les Etudes Et Les Analyses Environnementales, Département de Chimie, Faculté Des Sciences, Université Abdelmalek Essaadi, Mhannech II, B.P. 2121, Tétouan
[2] Laboratoire Matériaux Et Systèmes Interfaciaux LMSI, Faculté Des Sciences, Université Abdelmalek Essaadi, Mhannech II, B.P. 2121, Tétouan
[3] Departamento C.M., I.M. Y Química Inorgánica, Universidad de Cádiz, Puerto Real
[4] Advanced Membranes and Porous Materials Center, King Abdullah University of Science and Technology (KAUST), Thuwal
[5] Laboratoire de Chimie, Service de Toxicologie Et de Contrôle de Qualité, Institut National de Recherches en Santé Publique, BP 695, Nouakchott
关键词
Adsorption; Dried Sewage Sludge; Emerging contaminants; Methylene bleu; Wastewater treatment plant;
D O I
10.1007/s41204-021-00111-6
中图分类号
学科分类号
摘要
Sewage sludge valorization must be the favored solution of management for a residue that does not present the desired improvement in terms of wastewater treatment. The objective of this research work was to study the dye fixation capacity of the adsorbents produced from sewage sludge. The dried sewage sludge (DSS) was used as an adsorbent to remove a cationic dye, methylene blue (MB), from an aqueous solution in a batch system, as a function of contact time, pH, temperature and initial concentration. The proposed adsorbent was characterized using several techniques such as scanning electron microscopy (SEM), Brunauer–Emmett–Teller (BET) analysis, X-ray diffraction (XRD) and Fourier Transform Infrared Spectroscopy (FTIR). The adsorption equilibrium of MB was described using Langmuir, Freundlich and Sips equations. The equilibrium is perfectly adapted to the Langmuir model with a maximum adsorption capacity of 44.39 mg g−1 on a single layer. In order to study the adsorption mechanisms, first- and second-order kinetic models were used. The adsorbent produced from the sludge was capable of absorbing MB from the solution, with the expression of the second-order rate being preferred to that of the first order. In addition, the thermodynamic parameters were evaluated, demonstrating that the adsorption process is spontaneous and endothermic. Thus, this study convinced that the DDS proved to be an alternative, attractive, effective, economic, and environmentally friendly adsorbent for MB dye removal from aqueous solution. Graphic abstract: Schematic illustration of the prepared dried sewage sludge adsorbent for the removal of methylene blue from aquatic samples [Figure not available: see fulltext.]. © 2021, The Author(s), under exclusive licence to Springer Nature Switzerland AG.
引用
收藏
相关论文
共 70 条
[1]  
Chanaka Udayanga W.D., Veksha A., Giannis A., Lisak G., Chang V.W.C., Lim T.T., Fate and distribution of heavy metals during thermal processing of sewage sludge, Fuel, 226, pp. 721-744, (2018)
[2]  
Dubis B., Jankowski K.J., Zaluski D., Sokolski M., The effect of sewage sludge fertilization on the biomass yield of giant miscanthus and the energy balance of the production process, Energy, (2020)
[3]  
Werle S., Wilk R.K., A review of methods for the thermal utilization of sewage sludge: the polish perspective, Renew Energy, 35, 9, pp. 1914-1919, (2010)
[4]  
Werle S., Dudziak M., Gaseous fuels production from dried sewage sludge via air gasification, Waste Manag Res, 32, 7, pp. 601-607, (2014)
[5]  
Schnell M., Horst T., Quicker P., Thermal treatment of sewage sludge in Germany: a review, J Environ Manage, 263, (2020)
[6]  
Joo S.H., Dello Monaco F., Antmann E., Chorath P., Sustainable approaches for minimizing biosolids production and maximizing reuse options in sludge management: a review, J Environ Manage, 158, pp. 133-145, (2015)
[7]  
Agabo-Garcia C., Perez M., Rodriguez-Morgado B., Parrado J., Solera R., Biomethane production improvement by enzymatic pre-treatments and enhancers of sewage sludge anaerobic digestion, Fuel, 255, (2019)
[8]  
Rasapoor M., Young B., Brar R., Sarmah A., Zhuang W.Q., Baroutian S., Recognizing the challenges of anaerobic digestion: Critical steps toward improving biogas generation, Fuel, 261, (2019)
[9]  
Lu D., Wu D., Qian T., Jiang J., Cao S., Zhou Y., Liquid and solids separation for target resource recovery from thermal hydrolyzed sludge, Water Res, 171, (2020)
[10]  
Collivignarelli M.C., Canato M., Abba A., Carnevale Miino M., Biosolids: what are the different types of reuse?, J Clean Prod, 238, (2019)