Esmolol-Assisted Balloon and Stent Angioplasty for Aortic Coarctation

被引:0
作者
Muthukumaran C. Sivaprakasam
Gruschen R. Veldtman
Anthony P. Salmon
Richard Cope
Tom Pierce
Joseph J. Vettukattil
机构
[1] Southampton general hospital,Department of Paediatric Cardiology
[2] Wessex Cardiothoracic Centre,Shackleton Department of Anaesthetics
[3] Southampton University Hospital,undefined
[4] NHS Trust,undefined
[5] Southampton University Hospitals NHS trust,undefined
来源
Pediatric Cardiology | 2006年 / 27卷
关键词
Aorta; Stent; Coarctation; Esmolol; Balloon angioplasty;
D O I
暂无
中图分类号
学科分类号
摘要
The objective of this study was to evaluate the effectiveness and safety of esmolol-induced negative ino- and chronotropism during stent/balloon angioplasty for aortic coarctation. Balloon angioplasty and stent placement have become widely accepted therapies for native and recurrent coarctation of the aorta (CoA). Trauma to the vessel wall and stent migration related to forward displacement of the balloon and/or stent by cardiac output, are the most common complications. Controlling stroke volume and heart rate may assist in balloon stability and accurate deployment of stents. All methods currently used to achieve this have significant limitations. We describe our experience using esmolol to control stroke volume and heart rate during balloon/stent angioplasty of CoA. We performed a retrospective review of all patients who had intravenous esmolol during percutaneous treatment of CoA. Six interventions were performed in six patients: coarctation stent angioplasty in five patients (two native coarctation) and balloon angioplasty alone in one patient. The median systolic blood pressure achieved during the procedure was 65 mmHg (range, 57–75) representing a median reduction of 40 mmHg (range, 20–80; p = 0.008) from baseline. The median heart achieved was 50 beats/min (range, 20–80), representing a median reduction of 20 beats/min (range, 15–90, p = 0.048) from baseline. Optimal stent position was obtained in all patients. Intravenous esmolol controls periprocedural hemodynamics effectively and safely during percutaneous therapy for aortic coarctation, thereby aiding accurate stent placement. Further evaluation of its use during other percutaneous left heart interventions is required.
引用
收藏
页码:460 / 464
页数:4
相关论文
共 32 条
  • [1] Behrens JP(1995)Stenting of coarctation of the aorta Z Kardiol 84 798-125
  • [2] Cheatham G(2001)Adenosine-induced transient cardiac asystole enhances precise deployment of stent grafts in the aorta Cathet Cardiovasc Intervent 54 112-273
  • [3] Dorros JM(1996)Long-term outcome (up to 15 years) of balloon angioplasty of discrete native coarctation of the aorta in adolescents and adults J Endovasc Surg 3 270-1067
  • [4] Cohen ME(2004)Adenosine induced transient cardiac standstill in catheter interventional procedures for congenital heart disease J Am Coll Cardiol 43 1062-333
  • [5] Fawzy M(1998)Endovascular stents in the management of coarctation of the aorta in the adolescent and adult: one year follow up Heart 80 330-567
  • [6] Awad W(2001)Induction of ventricular fibrillation to facilitate endovascular stent graft repair of thoracic aortic aneurysms Heart 85 561-536
  • [7] Hassan JV(1998)Results of stenting for aortic Coarctation Anesthesiology 88 534-462
  • [8] Giovanni RA(2001)Clinical trial of esmolol-induced controlled hypotension with or without acute normovolumic hemodilution in spinal surgery Am J Cardiol 8 460-78
  • [9] Edgar A(2003)Clinical pharmacology, pharmacodynamics and interactions with esmolol Acta Anaesthesiol Scand 47 74-18F
  • [10] Cranston DA(1985)Stenting vs. balloon angioplasty for discrete unoperated coarctation of the aorta in adolescents and adults Am J Cardiol 56 14F-506