Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry

被引:0
|
作者
Ron Dueck
Oliver Goedje
Paul Clopton
机构
[1] Veterans Affairs San Diego Healthcare System,Anesthesiology Service
[2] University of California,Department of Anesthesiology
[3] University of Ulm,Research Service
[4] Global Restructuring Advisors,undefined
[5] VA San Diego Healthcare System,undefined
来源
Journal of Clinical Monitoring and Computing | 2012年 / 26卷
关键词
Arterial pressure waveform; Beat-to-beat blood pressure; Hemodynamic instability; Vascular disease;
D O I
暂无
中图分类号
学科分类号
摘要
The Tensys TL-200® noninvasive beat-to-beat blood pressure (BP) monitor displays continuous radial artery waveform as well as systolic, mean and diastolic BP from a pressure sensor directly over the radial artery at the wrist. It locates the site of maximal radial pulse signal, determines mean BP from maximal pulse waveform amplitude at optimal artery compression and then derives systolic and diastolic BP. We performed a cross-sectional study of TL-200 BP comparisons with contralateral invasive radial artery (A-Line) BP values in 19 subjects during an average 2.5 h of general anesthesia for a wide range of surgical procedures. Two hundred and fifty random sample pairs/patient resulted in 4,747 systolic, mean and diastolic BP pairs for analysis. A-Line BP ranged from 29 mm Hg diastolic to 211 mm Hg systolic, and heart rate varied between 38 and 210 beats/min. Bland–Altman analysis showed an average 2.3 mm Hg TL-200 versus A-Line systolic BP bias and limits of agreement (1.96 SD) were ± 15.3 mm Hg. Mean BP showed a 2.3 mm Hg TL-200 bias and ± 11.7 mm Hg limits of agreement, while diastolic BP showed a 1.7 mm Hg bias and ± 12.3 mm Hg limits of agreement. Coefficients of determination for TL-200 and A-Line BP regression were r² = 0.86 for systolic, r² = 0.86 for mean, and r² = 80 for diastolic BP, respectively, with no apparent change in correlation at low or high BP. Bland–Altman analysis suggested satisfactory agreement between TL-200 noninvasive beat-to-beat BP and invasive A-Line BP. Paired TL-200/A-Line BP comparisons showed a high coefficient of determination.
引用
收藏
页码:75 / 83
页数:8
相关论文
共 50 条
  • [1] Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry
    Dueck, Ron
    Goedje, Oliver
    Clopton, Paul
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (02) : 75 - 83
  • [2] Erratum to: Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry
    Ron Dueck
    Oliver Goedje
    Paul Clopton
    Journal of Clinical Monitoring and Computing, 2012, 26 : 495 - 495
  • [3] Erratum to: Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry (vol 26, pg 75, 2012)
    Dueck, Ron
    Goedje, Oliver
    Clopton, Paul
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (06) : 495 - 495
  • [4] SLEEP QUALITY AND CONTINUOUS, NONINVASIVE BEAT-TO-BEAT BLOOD-PRESSURE RECORDING
    VANDEBORNE, P
    NGUYEN, H
    LINKOWSKI, P
    DEGAUTE, JP
    JOURNAL OF HYPERTENSION, 1993, 11 (12) : 1423 - 1427
  • [5] BEAT-TO-BEAT AGREEMENT OF NONINVASIVE FINGER ARTERY AND INVASIVE RADIAL ARTERY BLOOD-PRESSURE IN HYPERTENSIVE PATIENTS TAKING CARDIOVASCULAR MEDICATION
    LINDQVIST, A
    CLINICAL PHYSIOLOGY, 1995, 15 (03): : 219 - 229
  • [6] NONINVASIVE VS INVASIVE BEAT-TO-BEAT MONITORING OF BLOOD-PRESSURE
    GABRIEL, A
    LINDBLAD, LE
    ANGLERYD, C
    CLINICAL PHYSIOLOGY, 1992, 12 (02): : 229 - 235
  • [7] Beat-to-beat noninvasive stroke volume from arterial pressure and Doppler ultrasound
    Johannes J. van Lieshout
    Karin Toska
    Erik Jan van Lieshout
    Morten Eriksen
    Lars Walløe
    Karel H. Wesseling
    European Journal of Applied Physiology, 2003, 90 : 131 - 137
  • [8] Beat-to-beat noninvasive stroke volume from arterial pressure and Doppler ultrasound
    van Lieshout, JJ
    Toska, K
    van Lieshout, EJ
    Eriksen, M
    Walloe, L
    Wesseling, KH
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2003, 90 (1-2) : 131 - 137
  • [9] Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit
    Nicolas Langwieser
    Luisa Prechtl
    Agnes S. Meidert
    Alexander Hapfelmeier
    Christian Bradaric
    Tareq Ibrahim
    Karl-Ludwig Laugwitz
    Roland M. Schmid
    Julia Y. Wagner
    Bernd Saugel
    Clinical Research in Cardiology, 2015, 104 : 518 - 524
  • [10] Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit
    Langwieser, Nicolas
    Prechtl, Luisa
    Meidert, Agnes S.
    Hapfelmeier, Alexander
    Bradaric, Christian
    Ibrahim, Tareq
    Laugwitz, Karl-Ludwig
    Schmid, Roland M.
    Wagner, Julia Y.
    Saugel, Bernd
    CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (06) : 518 - 524