Modeling and dynamic analysis of a pilot-operated pressure-regulating solenoid valve used in automatic transmission with bond graphs

被引:0
作者
Xiangwen Fan
Minglun Fang
Yongyi He
Tao Song
机构
[1] Shanghai University,Shanghai Key Laboratory of Intelligent Manufacturing and Robotics
[2] Shanghai Robot Industry Technology Research Institute,undefined
来源
Journal of the Brazilian Society of Mechanical Sciences and Engineering | 2019年 / 41卷
关键词
Modeling; Pilot-operated pressure-regulating solenoid valve; Bond graphs; Automatic transmission;
D O I
暂无
中图分类号
学科分类号
摘要
The pilot-operated pressure-regulating solenoid valve (PPRSV) is a key component of the automatic transmission (AT) in automobiles, and its performance significantly affects the efficiency and service lift of the AT and even road safety. However, few studies are devoted to the mathematical model of the PPRSV, and there is especially a lack of test equipment to verify its pressure control performance. Thus, the goal of this study is to find an effective and convenient modeling method and to verify the correctness of the model through simulations and experimentation. The bond graphs method, which is widely utilized to study hydraulic dynamics because it can easily identify the parameter process and consider the interactions in a hydraulic system, is selected here to help develop the numerical model of the PPRSV. The effective bulk modulus of hydraulic fluid was dynamically analyzed by considering the effect of the temperature, pressure and entrapped air. To consider the time delays of the electrical actuation and spool motion, the time delay element and Kirchhoff’s and Ohm’s laws are emphatically discussed to show the nonlinearity of forces. In addition, the Dahl model was used to more clearly express the static friction force to examine the hysteresis of the valve pressure. The comparative simulated and experimental studies confirm that the developed model can be used to study the control performance of the PPRSV, and the modeling method developed in this paper is feasible and handy.
引用
收藏
相关论文
共 60 条
[1]  
Dong P(2017)Design and analysis of a novel multi-speed automatic transmission with four degrees-of-freedom Mech Mach 108 83-96
[2]  
Liu Y(2000)A study on response improvement of proportional control solenoid valve for automatic transmission Eur J Org Chem 71 237-244
[3]  
Tenberge P(2014)Design and analysis of operation performance of parameters of the integrated valve under the high temperature condition Ann Nucl Energy 101 182-196
[4]  
Xingyang X(2018)Optimization of a pressure control valve for high power automatic transmission considering stability Mech Syst Signal Process 114 613-622
[5]  
Lee HW(2016)Stability analysis of governor-turbine-hydraulic system by state space method and graph theory Energy 69 2135-2146
[6]  
Cho BH(2012)Non-linear modeling and dynamic analysis of hydraulic control valve; effect of a decision factor between experiment and numerical simulation Nonlinear Dyn 54 421-429
[7]  
Lee WH(2011)Finite element modeling and simulation of proposed design magneto-rheological valve Int J Adv Manuf Technol 21 438-445
[8]  
Liu QF(2003)Finite element analysis and simulation evaluation of a magnetorheological valve Int J Adv Manuf Technol 128 1579-1587
[9]  
Bo HL(2018)Hold current effects on the power losses of high-speed solenoid valve for common-rail injector Appl Therm Eng 240 4031-4036
[10]  
Jian HC(2014)Research on key factors and their interaction effects of electromagnetic force of high-speed solenoid valve Sci World J 70 435-451