A blind accuracy assessment of computer-modeled forensic facial reconstruction using computed tomography data from live subjects

被引:54
|
作者
Wilkinson C. [3 ]
Rynn C. [3 ]
Peters H. [1 ]
Taister M. [1 ]
Kau C.H. [2 ]
Richmond S. [2 ]
机构
[1] FBI, Washington , DC
[2] Department of Health and Biological Sciences, University Dental Hospital, Cardiff
[3] School of Life Sciences, University of Dundee, Dow Street DD1 5EH, Dundee
关键词
accurary; computed tomography; computerized; CT; facial reconstruction; Forensic facial reconstruction;
D O I
10.1007/s12024-006-0007-9
中图分类号
学科分类号
摘要
A computer modeling system for facial reconstruction has been developed that employs a touch-based application to create anatomically accurate facial models focusing on skeletal detail. This article discusses the advantages and disadvantages of the system and illustrates its accuracy and reliability with a blind study using computed tomography (CT) data of living individuals. Three-dimensional models of the skulls of two white North American adults (one male, one female) were imported into the computer system. Facial reconstructions were produced by two practitioners following the Manchester method. Two posters were produced, each including a face pool of five surface model images and the facial reconstruction. The face pool related to the sex, age, and ethnic group of the target individual and included the surface model image of the target individual. Fifty-two volunteers were asked to choose the face from the face pool that most resembled each reconstruction. Both reconstructions received majority percentage hit rates that were at least 50% greater than any other face in the pool. The combined percentage hit rate was 50% above chance (70%). A quantitative comparison of the facial morphology between the facial reconstructions and the CT scan models of the subjects was carried out using Rapidform™ 2004 PP2-RF4. The majority of the surfaces of the facial reconstructions showed less than 2.5 mm error and 90% of the male face and 75% of the female face showed less than 5 mm error. Many of the differences between the facial reconstructions and the facial scans were probably the result of positional effects caused during the CT scanning procedure, especially on the female subject who had a fatter face than the male subject. The areas of most facial reconstruction error were at the ears and nasal tip. © 2006, Humana Press Inc.
引用
收藏
页码:179 / 187
页数:8
相关论文
共 5 条
  • [1] An Accuracy Assessment of Forensic Computerized Facial Reconstruction Employing Cone-Beam Computed Tomography from Live Subjects
    Lee, Won-Joon
    Wilkinson, Caroline M.
    Hwang, Hyeon-Shik
    JOURNAL OF FORENSIC SCIENCES, 2012, 57 (02) : 318 - 327
  • [2] Validation of a computer modelled forensic facial reconstruction technique using CT data from live subjects: A pilot study
    Short, Laura J.
    Khambay, Balvinder
    Ayoub, Ashraf
    Erolin, Caroline
    Rynn, Chris
    Wilkinson, Caroline
    FORENSIC SCIENCE INTERNATIONAL, 2014, 237 : 147.e1 - 147.e8
  • [3] Preliminary performance assessment of computer automated facial approximations using computed tomography scans of living individuals
    Parks, Connie L.
    Richard, Adam H.
    Monson, Keith L.
    FORENSIC SCIENCE INTERNATIONAL, 2013, 233 (1-3) : 133 - 139
  • [4] RECONSTRUCTION OF TEMPERATURE FIELDS FROM KNOWN BOUNDARY DATA USING COMPUTED TOMOGRAPHY
    Gu, R. J.
    Wang, H. C.
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 1993, 3 (01) : 245 - 256
  • [5] Accuracy of rib cage parameters from 3-Dimensional reconstruction images obtained using simultaneous biplanar radiographic scanning technique in adolescent idiopathic scoliosis: Comparison with conventional computed tomography
    Machino, Masaaki
    Kawakami, Noriaki
    Ohara, Tetsuya
    Saito, Toshiki
    Tauchi, Ryoji
    Imagama, Shiro
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 75 : 94 - 98