Endothelial damage and thromboembolic risk after pulmonary vein isolation using the latest ablation technologies: a comparison of the second-generation cryoballoon vs. contact force-sensing radiofrequency ablation

被引:0
作者
Kaori Hisazaki
Kanae Hasegawa
Kenichi Kaseno
Shinsuke Miyazaki
Naoki Amaya
Yuichiro Shiomi
Naoto Tama
Hiroyuki Ikeda
Yoshitomo Fukuoka
Tetsuji Morishita
Kentaro Ishida
Hiroyasu Uzui
Hiroshi Tada
机构
[1] University of Fukui,Department of Cardiovascular Medicine, Faculty of Medical Sciences
来源
Heart and Vessels | 2019年 / 34卷
关键词
Pulmonary vein isolation; Endothelial damage; Atrial fibrillation; Cryoballoon;
D O I
暂无
中图分类号
学科分类号
摘要
Experimental data suggest that cryoenergy is associated with less endothelial damage and thrombus formation than radiofrequency energy. This study aimed to compare the impact of pulmonary vein isolation (PVI) on the endothelial damage, myocardial damage, inflammatory response, and prothrombotic state between the two latest technologies, second-generation cryoballoon (CB2) and contact force-sensing radiofrequency catheter (CFRF) ablation. Eighty-six paroxysmal atrial fibrillation (AF) patients (55 men; 65 ± 12 years) underwent PVI with either the CB2 (n = 64) or CFRF (n = 22). Markers of the endothelial damage (l-arginine/asymmetric dimethylarginine [ADMA]), myocardial injury (creatine kinase-MB [CK-MB], troponin-T, and troponin-I), inflammatory response (high-sensitive C-reactive protein), and prothrombotic state (D-dimer, soluble fibrin monomer complex, and thrombin–antithrombin complex) were determined before and up to 24-h post-procedure. The total application time was shorter (1,460 ± 287 vs. 2,395 ± 571 [sec], p < 0.01) and total procedure time tended to be shorter (199 ± 37 vs. 218 ± 38 [min], p = 0.06) with CB2 than CFRF ablation. The amount of myocardial injury was greater (CK-MB: 45 ± 17 vs. 11 ± 3 [IU/l], p < 0.01) with CB2 than CFRF ablation. The l-arginine/ADMA ratio was lower (160 ± 51 vs. 194 ± 38, p = 0.028) after CB2 than CFRF ablation. Inflammatory and all prothrombotic markers were significantly elevated post-ablation; however, the magnitude was similar between the two groups. During a mean follow-up of 20 ± 6 months, the single-procedure AF freedom was similar between the CB2 and CFRF groups (60/64 vs. 20/22, p = 0.82). CB2-PVI produces significantly lesser endothelial damage with greater myocardial injury than CFRF-PVI; however, similar anticoagulant regimens are required during the peri-procedural periods in both technologies.
引用
收藏
页码:509 / 516
页数:7
相关论文
共 216 条
  • [31] Duytschaever M(undefined)undefined undefined undefined undefined-undefined
  • [32] Edgerton JR(undefined)undefined undefined undefined undefined-undefined
  • [33] Ellenbogen KA(undefined)undefined undefined undefined undefined-undefined
  • [34] Ellinor PT(undefined)undefined undefined undefined undefined-undefined
  • [35] Ernst S(undefined)undefined undefined undefined undefined-undefined
  • [36] Fenelon G(undefined)undefined undefined undefined undefined-undefined
  • [37] Gerstenfeld EP(undefined)undefined undefined undefined undefined-undefined
  • [38] Haines DE(undefined)undefined undefined undefined undefined-undefined
  • [39] Haissaguerre M(undefined)undefined undefined undefined undefined-undefined
  • [40] Helm RH(undefined)undefined undefined undefined undefined-undefined