Indoor exposure and health risk of polycyclic aromatic hydrocarbons (PAHs) in public facilities, Korea

被引:4
|
作者
Kim H.-H. [1 ]
Lim Y.-W. [1 ]
Jeon J.-M. [2 ]
Kim T.-H. [1 ]
Lee G.-W. [1 ]
Lee W.-S. [3 ]
Lim J.-Y. [3 ]
Shin D.-C. [4 ]
Yang J.-Y. [1 ]
机构
[1] The Institute for Environmental Research, Yonsei University College of Medicine, 250 Seongsan-Ro
[2] Department of Civil and Environmental Eng, Suncheon first College, Suncheon
[3] Indoor Air and Noise Research Division, National Institute of Environmental Research (NIER)
[4] Department of Preventive Medicine, Yonsei University College of Medicine, 250 Seongsan-Ro
关键词
Health risk assessment; Indoor and outdoor; Polycyclic aromatic hydrocarbons; Public facilities; Toxic equivalency factor;
D O I
10.5572/ajae.2013.7.2.072
中图分类号
学科分类号
摘要
In the study, pollution levels of indoor polycyclic aromatic hydrocarbons (PAHs) in public facilities (vapor phase or particulate phase) were evaluated, and a health risk assessment (HRA) was carried out based on exposure scenarios. Public facilities in Korea covered by the law, including underground subway stations, funeral halls, child care facilities, internet cafes (PC-rooms), and exhibition facilities (6 locations for each type of facility, for a total of 48 locations), were investigated for indoor assessment. For the HRA, individual excess cancer risk (ECR) was estimated by applying main toxic equivalency factor (TEF) values suggested in previous studies. Among the eight public facilities, internet cafes showed the highest average PM2.5 concentration at 110.0 μg/m3 (range: 83.5-138.5 μg/m3). When assuming a risk of facility exposure time based upon the results of the surveys for each public facility, the excess cancer risk using the benzo(a)pyrene indicator assessment method was estimated to be 10-7-10-6 levels for each facility. Based on the risk associated with various TEF values, the excess cancer risk based upon the seven types cancer EPA (1993) and Malcolm & Dobson's (1994) assessment method was estimated to be 10-7-10-5 for each facility. The excess cancer risk estimated from the TEF EPA (2010) assessment was the highest: 10-7-10-4 for each facility. This is due to the 10-fold difference between the TEF of dibenzo(a,e)fluoranthene in 2010 and in 1994. The internet cafes where smoking was the clear pollutant showed the highest risk level of 10-4, which exceeded the World Health Organization's recommended risk of 1×10-6. All facilities, with the exception of internet cafes, showed a 10-6 risk level. However, when the TEFs values of the US EPA (2010) were applied, the risk of most facilities in this study exceeded 1×10-6.
引用
收藏
页码:72 / 84
页数:12
相关论文
共 50 条
  • [1] Indoor exposure and health risk of polycyclic aromatic hydrocarbons (PAHs) via public facilities PM2.5, Korea (II)
    Kim H.-H.
    Lee G.-W.
    Yang J.-Y.
    Jeon J.-M.
    Lee W.-S.
    Lim J.-Y.
    Shin D.-C.
    Lee H.-S.
    Gwak Y.-K.
    Lim Y.-W.
    Asian Journal of Atmospheric Environment, 2014, 8 (1) : 35 - 47
  • [2] Phthalates and polycyclic aromatic hydrocarbons (PAHs) in the indoor settled carpet dust of mosques, health risk assessment for public
    Kadi, Mohammad W.
    Ali, Nadeem
    Albar, Hussain Mohammed Salem Ali
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 627 : 134 - 140
  • [3] Health risk assessment on dietary exposure to polycyclic aromatic hydrocarbons (PAHs) in Taiyuan, China
    Xia, Zhonghuan
    Duan, Xiaoli
    Qiu, Weixun
    Liu, Di
    Wang, Bin
    Tao, Shu
    Jiang, Qiujing
    Lu, Bin
    Song, Yunxue
    Hu, Xinxin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2010, 408 (22) : 5331 - 5337
  • [4] Polycyclic aromatic hydrocarbons (PAHs) in indoor environments are still imposing carcinogenic risk
    Wang, Mengjing
    Jia, Shenglan
    Lee, Suk Hyun
    Chow, Agnes
    Fang, Mingliang
    JOURNAL OF HAZARDOUS MATERIALS, 2021, 409
  • [5] Occupational exposure to polycyclic aromatic hydrocarbons (PAHs) by firefighters
    Akhtar, U. S.
    Keir, J. L.
    Matschke, D.
    White, P.
    Blais, J. M.
    TOXICOLOGY LETTERS, 2016, 259 : S211 - S211
  • [6] Indoor levels of polycyclic aromatic hydrocarbons (PAHs) from environment tobacco smoke of public bars
    Adesina, Olusola A.
    Nwogu, Amarachukwu S.
    Sonibare, Jacob A.
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2021, 208
  • [7] Polycyclic aromatic hydrocarbons (PAHs) in indoor and outdoor air of Hangzhou, China
    Liu, YJ
    Zhu, LZ
    Shen, XY
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (05) : 840 - 844
  • [8] Polycyclic aromatic hydrocarbons (PAHs) in indoor emission from decorative candles
    Orecchio, Santino
    ATMOSPHERIC ENVIRONMENT, 2011, 45 (10) : 1888 - 1895
  • [9] Measurement of Polycyclic Aromatic Hydrocarbons (PAHs) on Indoor Materials: Method Development
    Laguerre, Aureelie
    Gall, Elliott T. T.
    ACS OMEGA, 2023, 8 (23): : 20634 - 20641
  • [10] Polycyclic Aromatic Hydrocarbons (PAHs) in Indoor Dusts of Guizhou, Southwest of China: Status, Sources and Potential Human Health Risk
    Yang, Qin
    Chen, Huaguo
    Li, Baizhan
    PLOS ONE, 2015, 10 (02):