High-resolution and functional magnetic resonance imaging of the brachial plexus using an isotropic 3D T2 STIR (Short Term Inversion Recovery) SPACE sequence and diffusion tensor imaging

被引:0
作者
M. Viallon
M. I. Vargas
H. Jlassi
K. O. Lövblad
J. Delavelle
机构
[1] University Hospital of Geneva,Department of Radiology
来源
European Radiology | 2008年 / 18卷
关键词
Brachial plexus; Magnetic resonance; Three-dimensional; STIR; DTI;
D O I
暂无
中图分类号
学科分类号
摘要
This technical note demonstrates the relevance of the isotropic 3D T2 turbo-spin-echo (TSE) sequence with short-term inversion recovery (STIR) and variable flip angle RF excitations (SPACE: Sampling Perfection with Application optimized Contrasts using different flip angle Evolutions) for high-resolution brachial plexus imaging. The sequence was used in 11 patients in the diagnosis of brachial plexus pathologies involving primary and secondary tumors, and in six volunteers. We show that 3D STIR imaging is not only a reliable alternative to 2D STIR imaging, but it also better evaluates the anatomy, nerve site compression and pathology of the plexus, especially to depict space-occupying tumors along its course. Finally, due to its appropriate contrast we describe how 3D-STIR can be used as a high-resolution mask to be fused with fraction of anisotropy (FA) maps calculated from diffusion tensor imaging (DTI) data of the plexus.
引用
收藏
页码:1018 / 1023
页数:5
相关论文
共 17 条
[1]  
Aagaard BD(1998)MR neurography MR imaging of peripheral nerves Magn Reson Imaging Clin N Am 6 179-194
[2]  
Maravilla KR(2007)Role of magnetic resonance imaging in entrapment and compressive neuropathy-what, where, and how to see the peripheral nerves on the musculoskeletal magnetic resonance image: part 2. Upper extremity Eur Radiol 17 509-522
[3]  
Kliot M(2004)MR imaging of brachial plexus Top Magn Reson Imaging 15 113-125
[4]  
Kim S(2001)MRI of the brachial plexus Eur Radiol 11 325-336
[5]  
Todd M(1997)Three-dimensional MR myelography of traumatic injuries of the brachial plexus AJNR Am J Neuroradiol 18 1733-1742
[6]  
Shah GV(2004)Role of magnetic resonance neurography in brachial plexus lesions Muscle Nerve 30 305-309
[7]  
Mukherji SK(2005)Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences Invest Radiol 40 754-760
[8]  
van Es HW(2005)Brain MR diffusion tensor imaging and fibre tracking to differentiate between two diffuse axonal injuries Neuroradiology 47 604-608
[9]  
Gasparotti R(2006)Diffusion tensor imaging and tractography of central pontine myelinolysis J Neuroradiol 33 189-193
[10]  
Zhou L(2007)Propriospinal myoclonus: Utility of magnetic resonance diffusion tensor imaging and fiber tracking Mov Disord 22 1506-1509