Delayed surgical treatment of displaced midshaft clavicle fracture using Herbert cannulated screw with intramedullary bone graft

被引:0
|
作者
Martin Richardson
Louise Richardson
Saeed Asadollahi
机构
[1] Epworth Hospital,
[2] Bond University,undefined
[3] The Royal Melbourne Hospital,undefined
来源
European Journal of Orthopaedic Surgery & Traumatology | 2012年 / 22卷
关键词
Displaced clavicle fracture; Intramedullary; Delayed union; Open reduction internal fixation; Cannulated screw;
D O I
暂无
中图分类号
学科分类号
摘要
There is an increasing trend towards operative treatment for displaced midshaft clavicle fractures. This retrospective study was performed to assess the outcome of delayed fixation of displaced midshaft clavicle fractures and test the null hypothesis that there is no difference in results between early and delayed surgical treatment for displaced midshaft clavicle fractures. Using the hospital database, two groups of patients who were surgically treated using Herbert cannulated screw for displaced midshaft clavicle fractures were identified. There were 114 cases in acute (median time to operation of 5 days) and 21 cases in delayed groups (median time to operation 10.5 weeks). Thirty-five cases were available for follow-up in the acute and 16 cases in the delayed series. The primary outcome was assessed by the Disabilities of the Arm, Shoulder and Hand (DASH) score, American Shoulder and Elbow Surgeons score (ASES) and Constant-Murley score. Union occurred in 14 cases in the delayed group. The median DASH, mean ASES and Constant-Murley scores were 4.1, 97 and 88.7, respectively. Compared with the delayed group, the early group had a higher union rate (P = 0.033), trend towards lower DASH score (P = 0.051), and higher ASES score (P = 0.047). The delayed group had significantly more problems with prominent, symptomatic screws that required removal (P = 0.002). There were no significant differences in union time and complication rate. Delayed fixation of displaced midshaft fractures using the Herbert cannulated bone screw and bone graft is effective and provides a good functional outcome that only slightly reduced from that recorded for early fixation.
引用
收藏
页码:647 / 653
页数:6
相关论文
共 50 条
  • [31] Displaced Midshaft Clavicle Fracture Union Can Be Accurately Predicted with a Delayed Assessment at 6 Weeks Following Injury: A Prospective Cohort Study
    Nicholson, Jamie A.
    Clement, Nicholas D.
    Clelland, Andrew D.
    MacDonald, Deborah
    Simpson, A. Hamish R. W.
    Robinson, C. Michael
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2020, 102 (07): : 557 - 566
  • [32] Plating versus intramedullary pin or conservative treatment for midshaft fracture of clavicle: a meta-analysis of randomized controlled trials
    Duan, Xin
    Zhong, Gang
    Cen, Shiqiang
    Huang, Fuguo
    Xiang, Zhou
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (06) : 1008 - 1015
  • [33] AN UNUSUAL COMPLICATION FOLLOWING BONE-GRAFT TREATMENT OF A FRACTURE OF A CLAVICLE
    PETERS, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (02): : 196 - 197
  • [34] An Institutional Standardised Protocol for the Treatment of Acute Displaced Midshaft Clavicle Fractures (ADMCFs): Conservative or Surgical Management for Active Patients?
    Biz, Carlo
    Pozzuoli, Assunta
    Belluzzi, Elisa
    Scucchiari, Davide
    Bragazzi, Nicola Luigi
    Rossin, Alessandro
    Cerchiaro, Mariachiara
    Ruggieri, Pietro
    HEALTHCARE, 2023, 11 (13)
  • [35] Robot-assisted double screw fixation of minimally displaced scaphoid waist fracture nonunions or delayed unions without bone graft
    Guo, Yang
    Ma, Wei
    Tong, Dedi
    Liu, Kun
    Yin, Yaobin
    Yang, Chen
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2021, 46 (03) : 286 - 291
  • [36] 3D printing mirror model to assist MIPPO technology in the treatment of displaced midshaft clavicle fracture: a case report
    Hao, Shenshen
    Wang, Fei
    Liu, Zhibin
    Liu, Yanxiong
    Liu, Jun
    Wang, Yanfeng
    Bai, Lijie
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (03): : 2717 - 2720
  • [37] Treatment of scaphoid nonunion with nonvascularized distal radius bone graft and headless cannulated compression screw
    Yamak, Kamil
    Altay, Taskin
    Ozan, Firat
    Kayali, Cemil
    Karahan, Huseyin G.
    CHIRURGIA-ITALY, 2020, 33 (06): : 289 - 294
  • [38] Autologous bone cylinder transplantation with cannulated screw re-stabilisation: a new treatment option for delayed fracture healing of the femoral neck
    C. Frank
    M. von Au
    B. Vock
    A. Wentzensen
    P. A. Grützner
    T. Guehring
    Archives of Orthopaedic and Trauma Surgery, 2011, 131
  • [39] Autologous bone cylinder transplantation with cannulated screw re-stabilisation: a new treatment option for delayed fracture healing of the femoral neck
    Frank, C.
    von Au, M.
    Vock, B.
    Wentzensen, A.
    Gruetzner, P. A.
    Guehring, T.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (11) : 1509 - 1518
  • [40] The results of autologous bone graft and titanium headless cannulated compression screw for treatment of scaphoid nonunion
    Ozdemir, Guzelali
    Cicekli, Ozgur
    Akgul, Turgut
    Zehir, Sinan
    Yucel, Ferit
    Eskin, Deniz
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2014, 20 (03): : 199 - 204