Design method for interior decoration pollution control of buildings: Introduction and application

被引:0
作者
Fengna Chen
Huimin Zhang
Ximing Chen
Jun Ren
机构
[1] Shenzhen Institute of Building Research Co,
[2] Ltd.,undefined
来源
Building Simulation | 2020年 / 13卷
关键词
decoration pollution; design method; prescriptive index method; performance index method; pre-assessment;
D O I
暂无
中图分类号
学科分类号
摘要
Pollution from interior decoration of buildings has brought adverse effects on people’s health. In this paper, pre-assessment of pollution during decoration design process was adopted as the advance pollution control method in the building decoration construction. The classification of indoor air quality control targets and the classification of pollution emission rate of decoration materials were introduced. The two pollutant control design methods, namely prescriptive index method and performance index method were introduced, and differences between the two methods were compared. The implementation process of how to carry out the pollutant control design was stated by a case study in an office building.
引用
收藏
页码:637 / 646
页数:9
相关论文
共 84 条
[1]  
Bellingar TA(2015)New ANSI/BIFMA standard for testing of educational seating Ergonomics in Design: the Quarterly of Human Factors Applications 23 23-27
[2]  
Benden ME(2016)Impact of decoration materials and furniture on indoor air quality Journal of HV&AC 46 42-45
[3]  
Chen F(2018)Modeling and controlling indoor formaldehyde concentrations in apartments: On-site investigation in all climate zones of China Building and Environment 127 98-106
[4]  
Yang X(2012)Key factor analysis of VOC sorption and its impact on indoor concentrations: The role of ventilation Building and Environment 47 182-187
[5]  
Dai X(1987)Models and statistical methods for gaseous emission testing of finite sources in well-mixed Chambers Atmospheric Environment 21 425-430
[6]  
Liu J(2003)The development of low volatile organic compound emission house—A case study Building and Environment 38 1413-1422
[7]  
Yin Y(1993)Emissions of indoor pollutants from building materials—State of the art review Architectural Science Review 36 13-22
[8]  
Song X(1994)The impact of ventilation rate and partition layout on the VOC emission rate: time-dependent contaminant removal Indoor Air 4 276-283
[9]  
Jia S(2010)Decreasing concentrations of volatile organic compounds (VOC) emitted following home renovations Indoor Air 20 141-146
[10]  
Deng Q(2002)Modelling of volatile organic compounds emission from dry building materials Building and Environment 37 1349-1360