A vernier time-interval measurer with a computed interpolation coefficient, based on an XCS05XL PLIC from the XILINX company, is described. The resolving power of the measurer is 0.625–0.25 ns with a 20- to 50-interpolation coefficient and a 80-MHz reference signal. The PLIC application makes it possible to decrease the overall dimensions of the measurer without worsening the available accuracy.