Use of the GlideScope®-Ranger for pre-hospital intubations by anaesthesia trained emergency physicians - An observational study

被引:6
|
作者
Russo S.G. [1 ]
Nickel E.A. [1 ,2 ]
Leissner K.B. [3 ]
Schwerdtfeger K. [1 ]
Bauer M. [1 ]
Roessler M.S. [1 ]
机构
[1] University Hospital Göttingen, Department of Anaesthesiology, Göttingen
[2] HELIOS Klinikum Emil-von-Behring, Department of Anaesthesiology and Pain Medicine, Berlin
[3] Harvard Medical School, Department of Anesthesiology, VA Boston Healthcare System, Boston, MA
关键词
Airway management; GlideScope; Intubating laryngeal mask airway; Pre-hospital; Videolaryngoscopy;
D O I
10.1186/s12873-016-0069-2
中图分类号
学科分类号
摘要
Background: Pre-hospital endotracheal intubation is more difficult than in the operating room (OR). Therefore, enhanced airway management devices such as video laryngoscopes may be helpful to improve the success rate of pre-hospital intubation. We describe the use of the Glidescope®-Ranger (GS-R) as an alternative airway tool used at the discretion of the emergency physician (EP) in charge. Methods: During a 3.5 year period, the GS-R was available to be used either as the primary or backup tool for pre-hospital intubation by anaesthesia trained EP with limited expertise using angulated videolaryngoscopes. Results: During this period 672 patients needed pre-hospital intubation of which the GS-R was used in 56 cases. The overall GS-R success rate was 66 % (range of 34-100 % among EP). The reasons for difficulties or failure included inexperience of the EP with the GS-R, impaired view due to secretion, vomitus, blood or the inability to see the screen in very bright environment due to sunlight. Conclusion: Special expertise and substantial training is needed to successfully accomplish tracheal intubation with the GS-R in the pre-hospital setting. Providers inexperienced with DL as well as video-assisted intubation should not expect to be able to perform tracheal intubation easily just because a videolaryngoscope is available. Additionally, indirect laryngoscopy might be difficult or even impossible to achieve in the pre-hospital setting due to impeding circumstances such as blood, secretions or bright sun-light. Therefore, videolaryngoscopes, here the GS-R, should not be considered as the "Holy Grail" of endotracheal intubation, neither for the experts nor for inexperienced providers. © 2016 Russo et al.
引用
收藏
相关论文
共 49 条
  • [31] Advancing a machine learning-based decision support tool for pre-hospital assessment of dyspnoea by emergency medical service clinicians: a retrospective observational study
    Kauppi, Wivica
    Imberg, Henrik
    Herlitz, Johan
    Molin, Oskar
    Axelsson, Christer
    Magnusson, Carl
    BMC EMERGENCY MEDICINE, 2025, 25 (01):
  • [32] Study on the Need for Pre-hospital Personnel Within the Office of Sis-Ecu911 to Mitigate the Emergency
    Cobos Lazo, Richard Santiago
    Cuenca Soto, Maria del Cisne
    Morocho Ochoa, Pablo Geronimo
    INNOVATION AND RESEARCH-SMART TECHNOLOGIES & SYSTEMS, VOL 2, CI3 2023, 2024, 1041 : 15 - 29
  • [33] A before-and-after observational study of a protocol for use of the C-MAC videolaryngoscope with a Frova introducer in pre-hospital rapid sequence intubation
    Angerman, S.
    Kirves, H.
    Nurmi, J.
    ANAESTHESIA, 2018, 73 (03) : 348 - 355
  • [34] The characteristics and pre-hospital management of blunt trauma patients with suspected spinal column injuries: a retrospective observational study
    Oosterwold, J. T.
    Sagel, D. C.
    van Grunsven, P. M.
    Holla, M.
    de Man-van Ginkel, J.
    Berben, S.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2017, 43 (04) : 513 - 524
  • [35] The characteristics and pre-hospital management of blunt trauma patients with suspected spinal column injuries: a retrospective observational study
    J. T. Oosterwold
    D. C. Sagel
    P. M. van Grunsven
    M. Holla
    J. de Man-van Ginkel
    S. Berben
    European Journal of Trauma and Emergency Surgery, 2017, 43 : 513 - 524
  • [36] EZ-IO® intraosseous device implementation in a pre-hospital emergency service: A prospective study and review of the literature
    Santos, David
    Carron, Pierre-Nicolas
    Yersin, Bertrand
    Pasquier, Mathieu
    RESUSCITATION, 2013, 84 (04) : 440 - 445
  • [37] An important issue of burnout among pre-hospital emergency medical personnel in Chengdu: a cross-sectional study
    Liu, Zhijiang
    Luo, Li
    Dai, Hang
    Zhang, Bihua
    Ma, Lin
    Xiang, Tao
    BMC EMERGENCY MEDICINE, 2024, 24 (01)
  • [38] Pre-hospital risk assessment in suspected non-ST-elevation acute coronary syndrome: A prospective observational study
    van Dongen, Dominique N.
    Tolsma, Rudolf T.
    Fokkert, Marion J.
    Badings, Erik A.
    van der Sluis, Aize
    Slingerland, Robbert J.
    van 't Hof, Arnoud W. J.
    Ottervanger, Jan Paul
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2020, 9 (1_SUPPL) : 5 - 12
  • [39] Pre-Hospital Emergency Medical Services in Developing Countries: A Case Study about EMS Response Time in Yazd, Iran
    Bahrami, M. A.
    Maleki, A.
    Ezzatabadi, M. Ranjbar
    Askari, R.
    Tehrani, G. H. Ahmadi
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2011, 13 (10) : 735 - 738
  • [40] A prospective study of physician pre-hospital anaesthesia in trauma patients: oesophageal intubation, gross airway contamination and the ‘quick look’ airway assessment
    David J Lockey
    Pascale Avery
    Timothy Harris
    Gareth E Davies
    Hans Morten Lossius
    BMC Anesthesiology, 13