Climate change impacts on extreme energy consumption of office buildings in different climate zones of China

被引:0
作者
Mingcai Li
Jun Shi
Jingfu Cao
Xiaoyi Fang
Min Wang
Xin Wang
机构
[1] Tianjin Meteorological Bureau,Institute of Building Environment and Energy Efficiency
[2] Chinese Academy of Meteorological Sciences,MOE Joint International Research Lab of Eco Urban Design, College of Architecture and Urban Planning
[3] China Academy of Building Research,undefined
[4] Tongji University,undefined
来源
Theoretical and Applied Climatology | 2020年 / 140卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, 16 cities representing four major architectural climate zones of China were selected, and the heating and cooling loads of office building during the period of 1961–2017 were simulated by using TRNSYS software. Daily extreme heating and cooling loads were determined by percentile methods, and the climate change impact on extreme loads was analyzed. The results showed that the days of extreme heating load of office building significantly decreased in almost all the selected cities, whereas there were no significant changes in the days of extreme cooling load. The daily extreme heating load was dominantly affected by the temperature (R2 = 0.43–0.79), but the daily extreme cooling load was related to multiple climate factors, including temperature, relative humidity, and solar radiation. Single temperature can only explain 3–37% of the changes of daily extreme cooling load, and the combination of multiple climate factors can explain 58–85%. Importantly, the effect of temperature on extreme cooling load showed decrease from the cold to hot climate zones, but the impacts of relative humidity and solar radiation gradually increased. These results suggest that the maximum design capacity of heating systems can properly decrease, and the design capacity of cooling systems may not largely increase with the climate warming. In addition, the combined effect of multiple climate factors rather than the single temperature, as well as the different responses of extreme cooling energy consumption to climate change in different climate zones, should be considered when making measures for improving operating efficiency of air-conditioning system.
引用
收藏
页码:1291 / 1298
页数:7
相关论文
共 89 条
  • [1] Al-Hadhrami LM(2013)Comprehensive review of cooling and heating degree days characteristics over Kingdom of Saudi Arabia Renew Sust Energ Rev 27 305-314
  • [2] Cai WG(2009)China building energy consumption: situation, challenges and corresponding measures Energy Policy 37 2054-2059
  • [3] Wu Y(2017)Effects of climate change on outdoor meteorological parameters for building energy-saving design in the different climate zones of China Energy & Buildings 146 65-72
  • [4] Zhong Y(2011)Developing future hourly weather files for studying the impact of climate change on building energy performance in Hong Kong Energy and Buildings 43 2860-2868
  • [5] Ren H(2001)Effect of fixed horizontal louver shading devices on thermal performance of building by TRNSYS simulation Renew Energy 23 497-507
  • [6] Cao JF(2017)Effective design and operation strategy of renewable cooling and heating system for building application in hot-humid climate Sol Energy 143 1-9
  • [7] Li MC(2005)Contrasting the capabilities of building energy performance simulation programs Build Simul 43 231-238
  • [8] Wang M(2012)Hidden climate change-urban meteorology and the scales of real weather Clim Chang 113 23-33
  • [9] Xiong MM(2005)Current building energy consumption in China and effective energy efficiency measures HV&AC 35 30-40
  • [10] Meng FC(2010)Multiple regression models for energy use in air-conditioned office buildings in different climates Energy Convers Manag 51 2692-2697