Determination of mono- and diacylglycerols from E 471 food emulsifiers in aerosol whipping cream by high-performance thin-layer chromatography–fluorescence detection

被引:0
作者
Claudia Oellig
Max Blankart
Jörg Hinrichs
Wolfgang Schwack
Michael Granvogl
机构
[1] Institute of Food Chemistry,Department of Food Chemistry and Analytical Chemistry (170a)
[2] University of Hohenheim,Department of Soft Matter Science and Dairy Technology (150e)
[3] Institute of Food Science and Biotechnology,undefined
[4] University of Hohenheim,undefined
来源
Analytical and Bioanalytical Chemistry | 2020年 / 412卷
关键词
Food emulsifiers; Mono- and diacylglycerols (MAG and DAG); E 471; Aerosol whipping cream; LLE; High-performance thin-layer chromatography–fluorescence detection (HPTLC–FLD);
D O I
暂无
中图分类号
学科分类号
摘要
Mono- and diacylglycerol (MAG and DAG) emulsifiers (E 471) are widely applied to regulate techno-functional properties in different food categories, for example, in dairy products. A method for the determination of MAG and DAG in aerosol whipping cream by high-performance thin-layer chromatography with fluorescence detection (HPTLC–FLD) after derivatization with primuline was developed. For sample preparation, aerosol whipping cream was mixed with ethanol, followed by the addition of water and liquid-liquid extraction with tert-butyl methyl ether. The sample extracts were analyzed by HPTLC–FLD on silica gel LiChrospher plates with n-pentane/n-hexane/diethyl ether (22.5:22.5:55, v/v/v) as mobile phase, when interfering matrix like cholesterol and triacylglycerols were successfully separated from the E 471 food additives. For quantitation, an emulsifier with known composition was used as calibration standard and the fluorescent MAG and DAG were scanned at 366/> 400 nm. Limits of detection and quantitation of 4 and 11 mg/100 g aerosol whipping cream were obtained for both monostearin and 1,2-distearin, respectively, and allowed the reliable quantitation of MAG and DAG from E 471 far below commonly applied emulsifier amounts. Recoveries from model aerosol whipping cream with 400 mg E 471/100 g were determined in a calibration range of 200–600 mg E 471/100 g sample and ranged between 86 and 105% with relative standard deviations below 7%. In aerosol whipping creams from the German market, E 471 amounts ranged between 384 and 610 mg/100 g.
引用
收藏
页码:7441 / 7451
页数:10
相关论文
共 20 条
[1]  
Folch J(1957)A simple method for the isolation and purification of total lipids from animal tissues J Biol Chem 226 497-413
[2]  
Lees M(1965)Improved procedure for the extraction of lipids from human erythrocytes J Lipid Res 6 428-424
[3]  
Sloane Stanley GH(1997)A two-dimensional thin-layer chromatography procedure for simultaneous separation of ceramide and diacylglycerol species J Lipid Res 38 1702-1706
[4]  
Rose HG(1997)Quantification in the subnanomolar range of phospholipids and neutral lipids by monodimensional thin-layer chromatography and image analysis J Lipid Res 38 1482-1489
[5]  
Oklander M(1982)Determination of mono- and diglycerides in baked goods I Riv Soc Ital Sci Aliment 11 31-36
[6]  
Bodennec J(1981)Quantitative determination of emulsifiers in bakery and pastry products Veroeff Arbeitsgem Getreideforsch 183 42-49
[7]  
Brichon G(1997)Applicazione della estrazione in fase solida (SPE) alla determinazione dei diacilgliceroli negli alimenti Riv Ital delle Sostanze Grasse 74 411-414
[8]  
Koul O(undefined)undefined undefined undefined undefined-undefined
[9]  
El Babili M(undefined)undefined undefined undefined undefined-undefined
[10]  
Zwingelstein G(undefined)undefined undefined undefined undefined-undefined