Fast electrophoresis in conventional capillaries by employing a rapid injection device and contactless conductivity detection

被引:0
|
作者
Andrea Rainelli
Peter C. Hauser
机构
[1] University of Basel,Department of Chemistry
来源
关键词
Capillary electrophoresis; Fast separation; Automated injection; Contactless conductivity detection;
D O I
暂无
中图分类号
学科分类号
摘要
A purpose-made set-up featuring an automated fast injector allowed the easy optimization of the injected amount and the adjustment of the separation length of conventional capillaries from a minimum of 5 cm upward. It was found that a compromise in capillary length for separation efficiency and analysis time also has to take into account the injected amount, which in turn affects the sensitivity and hence the detection limit. The versatility of the system was demonstrated by the analysis of the major cations and anions in natural water samples in less than 1 min, the concurrent determination of a mixture of amino acids and carbohydrates in 160 s, and of three active ingredients in a pharmaceutical preparation in 40 s. Plate numbers were typically around 50,000 and detection limits down to 1 μM could be achieved.
引用
收藏
页码:789 / 794
页数:5
相关论文
共 50 条
  • [1] Fast electrophoresis in conventional capillaries by employing a rapid injection device and contactless conductivity detection
    Rainelli, A
    Hauser, PC
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (03) : 789 - 794
  • [2] Capillary electrophoresis and contactless conductivity detection of ions in narrow inner diameter capillaries
    Mayrhofer, K
    Zemann, AJ
    Schnell, E
    Bonn, GK
    ANALYTICAL CHEMISTRY, 1999, 71 (17) : 3828 - 3833
  • [4] Contactless Conductivity Detection in Capillary Electrophoresis in Combination with Capillaries with Thin Inner Diameter
    Tuma, Petr
    Samcova, Eva
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 168 - 172
  • [5] Rapid Detection of AGs using Microchip Capillary Electrophoresis Contactless Conductivity Detection
    Zhu, Gangzhi
    Bao, Chunjie
    Liu, Wenfang
    Yan, Xingxing
    Liu, Lili
    Xiao, Jian
    Chen, Chuanpin
    CURRENT PHARMACEUTICAL ANALYSIS, 2019, 15 (01) : 9 - 16
  • [6] Fast Determination of Ciprofloxacin by Batch Injection Analysis with Amperometric Detection and Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection
    Montes, Rodrigo H. O.
    Marra, Mariana C.
    Rodrigues, Monike M.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    ELECTROANALYSIS, 2014, 26 (02) : 432 - 438
  • [7] Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements
    Abad-Villar, EM
    Tanyanyiwa, J
    Fernández-Abedul, MT
    Costa-García, A
    Hauser, PC
    ANALYTICAL CHEMISTRY, 2004, 76 (05) : 1282 - 1288
  • [8] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Schnell, E
    Volgger, D
    Bonn, GK
    ANALYTICAL CHEMISTRY, 1998, 70 (03) : 563 - 567
  • [9] Rapid speciation of Se(IV) and Se(VI) by flow injection–capillary electrophoresis system with contactless conductivity detection
    Pavel Kubáň
    Petr Kubáň
    Vlastimil Kubáň
    Analytical and Bioanalytical Chemistry, 2004, 378 : 378 - 382
  • [10] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Mayrhofer, K
    Schnell, E
    Bonn, GK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U162 - U162