Anterior C2–C3 fixation with screws: proposal of a new technique and comparative mechanical assays

被引:0
|
作者
Helton L. A. Defino
Orli J. Néri
Antonio C. Shimano
机构
[1] University of São Paulo,Faculty of Medicine of Ribeirão Preto, Dept. of Biomechanics, Medicine and Reahabilitation of the Locomotor Apparatus
来源
European Spine Journal | 2006年 / 15卷
关键词
Cervical spine; Biomechanical testing; Spinal fusion;
D O I
暂无
中图分类号
学科分类号
摘要
The technical difficulties involved in the anterior fixation of the C2–C3 vertebral segment by means of plates and screws, related to retraction of the structures around the vertebral segment, appropriate exposure of the site and positioning of the screws and plate, motivated the development of a new modality of fixation of this segment using only screws. Fixation of the C2–C3 vertebral segment according to the technique proposed requires less exposure of the vertebral segment and does not involve the technical difficulties of standard fixation with plates and screws. In order to study the mechanical properties of this new modality of vertebral fixation, mechanical tests were performed comparing the proposed technique (fixation solely with screws positioned in the craniocaudal direction) and routinely used fixation (H plate and screws). The tests were performed using 80 cervical spine segments from Landrace pigs aged 5 months. The vertebral segments fixed by the two techniques were divided into experimental groups of ten specimens each and submitted to mechanical tests of flexion, extension, lateral bending and rotation in a universal testing machine. The mechanical properties used to compare the results were the load necessary to produce a pre-established deformation and stiffness. No significant differences were observed between the values obtained for the production of the pre-established deformation in the flexion and rotation tests. In the extension and lateral bending tests, the mean values obtained for vertebral segments fixed only with screws were significantly higher. Analysis of stiffness showed no significant difference in the flexion, rotation and lateral bending tests, whereas in the extension tests, the mean values for the group fixed only with screws were significantly higher. The results of the mechanical tests performed showed that fixation of the C2-C3 segment only with screws was not inferior from a mechanical point of view when compared to fixation with H plates of the Orozco type.
引用
收藏
页码:1159 / 1164
页数:5
相关论文
共 34 条
  • [21] Congenital Absence of the Posterior Element of C1, C2, and C3 Along with Bilateral Absence of C4 Pedicles: Case Report and Review of the Literature
    Sharifi, Guive
    Lotfinia, Mahmoud
    Rahmanzade, Ramin
    Lotfinia, Ahmad Ali
    Rahmanzadeh, Reza
    Omidbeigi, Mahmoud
    Meybodi, Emami Tohid
    WORLD NEUROSURGERY, 2018, 111 : 395 - 401
  • [22] The New Alternative Technique Outcomes: Atlas Lateral Mass Screw and C2-3 Transfacet Screw Fixation for Complex Atlantoaxial Instability in Patients with Thin C2 Pedicle or High-Riding Vertebral Artery
    Cine, Hidayet Safak
    Avci, Idris
    Uysal, Ece
    Unsal, Ulkun Unlu
    Gunaydin, Mehmet Emre
    Paksoy, Kemal
    Senturk, Salim
    Yaman, Onur
    WORLD NEUROSURGERY, 2024, 191 : E246 - E255
  • [23] A new technique for stabilization of injuries at C2-C3 in young children
    Hamoud, Kamal
    Abbas, Janan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (11): : 1791 - 1795
  • [24] Expert’s comment concerning Grand Rounds case entitled ‘‘Salvage of failed odontoid fixation through anterior C1/C2 transarticular screws” (by Khalid M. I. Salem et al.)
    Max Aebi
    European Spine Journal, 2015, 24 : 615 - 616
  • [25] Symmetric dumbbell ganglioneuromas of bilateral C2 and C3 roots with intradural extension associated with Von Recklinghausen's disease: Case report
    Kyoshima, K
    Sakai, K
    Kanaji, M
    Oikawa, S
    Kobayashi, S
    Sato, A
    Nakayama, J
    SURGICAL NEUROLOGY, 2004, 61 (05): : 468 - 473
  • [26] Balloon kyphoplasty and additional anterior odontoid screw fixation for treatment of unstable osteolytic lesions of the vertebral body C2: a case series
    Voelker, Anna
    von der Hoeh, Nicolas H.
    Heyde, Christoph-Eckhard
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [27] Balloon kyphoplasty and additional anterior odontoid screw fixation for treatment of unstable osteolytic lesions of the vertebral body C2: a case series
    Anna Voelker
    Nicolas H. von der Hoeh
    Christoph-Eckhard Heyde
    BMC Musculoskeletal Disorders, 19
  • [28] Biomechanical analysis of the C2 intralaminar fixation technique using a cross-link and offset connector for an unstable atlantoaxial joint
    Lehman, Ronald A., Jr.
    Dmitriev, Anton E.
    Wilson, Kevin W.
    SPINE JOURNAL, 2012, 12 (02) : 151 - 156
  • [29] Management of neglected complex hangman's fracture by reforming the C2 pedicle: new innovative technique of motion preservation at the C1-2 joint in 2 cases
    Singh, Pankaj K.
    Agrawal, Mohit
    Sawarkar, Dattaraj
    Kumar, Amandeep
    Verma, Satish
    Doddamani, Ramesh
    Chandra, P. Sarat
    Kale, Shashank S.
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 32 (06) : 965 - 972
  • [30] Biomechanical evaluation of two alternative techniques to the Goel-Harms technique for atlantoaxial fixation: C1 lateral mass-C2 bicortical translaminar screw fixation and C1 lateral mass-C2/3 transarticular screw fixation
    Du, Yue-Qi
    Li, Teng
    Ma, Chao
    Qiao, Guang-Yu
    Yin, Yi-Heng
    Yu, Xin-Guang
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 32 (05) : 682 - 688