Anterior C2–C3 fixation with screws: proposal of a new technique and comparative mechanical assays

被引:0
|
作者
Helton L. A. Defino
Orli J. Néri
Antonio C. Shimano
机构
[1] University of São Paulo,Faculty of Medicine of Ribeirão Preto, Dept. of Biomechanics, Medicine and Reahabilitation of the Locomotor Apparatus
来源
European Spine Journal | 2006年 / 15卷
关键词
Cervical spine; Biomechanical testing; Spinal fusion;
D O I
暂无
中图分类号
学科分类号
摘要
The technical difficulties involved in the anterior fixation of the C2–C3 vertebral segment by means of plates and screws, related to retraction of the structures around the vertebral segment, appropriate exposure of the site and positioning of the screws and plate, motivated the development of a new modality of fixation of this segment using only screws. Fixation of the C2–C3 vertebral segment according to the technique proposed requires less exposure of the vertebral segment and does not involve the technical difficulties of standard fixation with plates and screws. In order to study the mechanical properties of this new modality of vertebral fixation, mechanical tests were performed comparing the proposed technique (fixation solely with screws positioned in the craniocaudal direction) and routinely used fixation (H plate and screws). The tests were performed using 80 cervical spine segments from Landrace pigs aged 5 months. The vertebral segments fixed by the two techniques were divided into experimental groups of ten specimens each and submitted to mechanical tests of flexion, extension, lateral bending and rotation in a universal testing machine. The mechanical properties used to compare the results were the load necessary to produce a pre-established deformation and stiffness. No significant differences were observed between the values obtained for the production of the pre-established deformation in the flexion and rotation tests. In the extension and lateral bending tests, the mean values obtained for vertebral segments fixed only with screws were significantly higher. Analysis of stiffness showed no significant difference in the flexion, rotation and lateral bending tests, whereas in the extension tests, the mean values for the group fixed only with screws were significantly higher. The results of the mechanical tests performed showed that fixation of the C2-C3 segment only with screws was not inferior from a mechanical point of view when compared to fixation with H plates of the Orozco type.
引用
收藏
页码:1159 / 1164
页数:5
相关论文
共 34 条
  • [1] Anterior C2-C3 fixation with screws:: proposal of a new technique and comparative mechanical assays
    Defino, Helton L. A.
    Néri, Orli J.
    Shimano, Antonio C.
    EUROPEAN SPINE JOURNAL, 2006, 15 (07) : 1159 - 1164
  • [2] Comparison of Fatigue Strength of C2 Pedicle Screws, C2 Pars Screws, and a Hybrid Construct in C1-C2 Fixation
    Su, Brian W.
    Shimer, Adam L.
    Chinthakunta, Suresh
    Salloum, Kanaan
    Ames, Christopher P.
    Vaccaro, Alexander R.
    Bucklen, Brandon
    SPINE, 2014, 39 (01) : E12 - E19
  • [3] Occipitocervical fusion: Fix to C2 or C3?
    Pan, Junwei
    Huang, Dageng
    Hao, Dingjun
    Zhao, Yaling
    He, Baorong
    Wu, Qining
    Li, Hui
    Ge, Chaoyuan
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2014, 127 : 134 - 139
  • [4] Bilateral C1 laminar hooks combined with C2 pedicle screws fixation for treatment of C1–C2 instability not suitable for placement of transarticular screws
    Bin Ni
    Zhuangchen Zhu
    Fengjin Zhou
    Qunfeng Guo
    Jian Yang
    Jun Liu
    Fei Wang
    European Spine Journal, 2010, 19 : 1378 - 1382
  • [5] Instrumented reduction of a fixed C1-2 subluxation using occipital and C2/C3 fixation: A case report
    Meals, Clifton
    Harrison, Rachel
    Yu, Warren
    O'Brien, Joseph
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2013, 7 : e20 - e23
  • [6] The Anterior Transarticular Fixation of C1/C2 in the Elderly With Dens Fractures
    Gembruch, Oliver
    Ahmadipour, Yahya
    Lemonas, Elias
    Mueller, Oliver
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2020, 14 (02) : 162 - 169
  • [7] Pseudosubluxation of C2 on C3 in polytraumatized children - Prevalence and significance
    Shaw, M
    Burnett, H
    Wilson, A
    Chan, O
    CLINICAL RADIOLOGY, 1999, 54 (06) : 377 - 380
  • [8] Bilateral C1 laminar hooks combined with C2 pedicle screws fixation for treatment of C1-C2 instability not suitable for placement of transarticular screws
    Ni, Bin
    Zhu, Zhuangchen
    Zhou, Fengjin
    Guo, Qunfeng
    Yang, Jian
    Liu, Jun
    Wang, Fei
    EUROPEAN SPINE JOURNAL, 2010, 19 (08) : 1378 - 1382
  • [9] Biomechanical comparison of four C1 to C2 rigid fixative techniques: Anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws
    Lapsiwala, SB
    Anderson, PA
    Oza, A
    Resnick, DK
    NEUROSURGERY, 2006, 58 (03) : 516 - 520
  • [10] Total spondylectomy of C2:: a new surgical technique
    Stulik, J.
    Kozak, J.
    Sebesta, P.
    Vyskocil, T.
    Kryl, J.
    Pelichovska, M.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2007, 74 (02) : 79 - 90