Electrochemical sandwich immunoassay for the peptide hormone prolactin using an electrode modified with graphene, single walled carbon nanotubes and antibody-coated gold nanoparticles

被引:0
|
作者
Shengqiang Li
Yurong Yan
Liang Zhong
Ping Liu
Ye Sang
Wei Cheng
Shijia Ding
机构
[1] Chongqing Medical University,Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), Department of Laboratory Medicine
[2] the First Affiliated Hospital of Chongqing Medical University,Molecular Oncology and Epigenetics Laboratory
[3] Bioscience (Tianjin) Diagnostic Technology Co.Ltd,undefined
来源
Microchimica Acta | 2015年 / 182卷
关键词
Electrochemical biosensor; Immunosensor; Graphene; Single wall carbon nanotubes; Gold nanoparticles; Prolactin; Chitosan; Alkaline phosphatase;
D O I
暂无
中图分类号
学科分类号
摘要
We describe a new kind of electrochemical immunoassay for the peptide hormone prolactin. A glassy carbon electrode (GCE) was modified with a hybrid material consisting of graphene, single walled carbon nanotubes and gold nanoparticles (AuNPs) in a chitosan (CS) matrix. The graphene and the single wall carbon nanotubes were first placed on the GCE, and the AuNPs were then electrodeposited on the surface by cyclic voltammetry. This structure results in a comparably large surface for immobilization of the capturing antibody (Ab1). The modified electrode was used in a standard sandwich-type of immunoassay. The secondary antibody (Ab2) consisted of AuNPs with immobilized Ab2 and modified with biotinylated DNA as signal tags. Finally, alkaline phosphatase was bound to the biotinylated DNA-AuNPs-Ab2 conjugate via streptavidin chemistry. The enzyme catalyzes the hydrolysis of the α-naphthyl phosphate to form α-naphthol which is highly electroactive at an operating voltage as low as 180 mV (vs. Ag/AgCl). The resulting immunoassay exhibits high sensitivity, wide linear range (50 to 3200 pg∙mL‾1), low detection limit (47 pg∙mL‾1), acceptable selectivity and reproducibility. The assay provides a pragmatic platform for signal amplification and has a great potential for the sensitive determination of antigens other than prolactine.
引用
收藏
页码:1917 / 1924
页数:7
相关论文
共 50 条
  • [41] Electrochemical sensing of D-penicillamine on modified glassy carbon electrode by using a nanocomposite of gold nanoparticles and reduced graphene oxide
    Marzieh Jafari
    Javad Tashkhourian
    Ghodratollah Absalan
    Journal of the Iranian Chemical Society, 2017, 14 : 1253 - 1262
  • [42] Electrochemical Determination of Celecoxib on a Graphene Based Carbon Ionic Liquid Electrode Modified with Gold Nanoparticles and Its Application to Pharmaceutical Analysis
    Elham Arkan
    Ziba Karimi
    Mojtaba Shamsipur
    Reza Saber
    Analytical Sciences, 2013, 29 : 855 - 860
  • [43] Electrochemical immunosensor for prostate-specific antigen using a glassy carbon electrode modified with a nanocomposite containing gold nanoparticles supported with starch-functionalized multi-walled carbon nanotubes
    Tian, Jianniao
    Huang, Jiaoling
    Zhao, Yanchun
    Zhao, Shulin
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 81 - 88
  • [44] Electrochemical Determination of Tyrosine Using Graphene and Gold Nanoparticle Composite Modified Glassy Carbon Electrode
    Liu, M.
    Lao, J.
    Wang, H.
    Xu, Z.
    Li, J.
    Wen, L.
    Yin, Z.
    Luo, C.
    Peng, H.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2021, 57 (01) : 41 - 50
  • [45] Electrochemical immunosensor for prostate-specific antigen using a glassy carbon electrode modified with a nanocomposite containing gold nanoparticles supported with starch-functionalized multi-walled carbon nanotubes
    Jianniao Tian
    Jiaoling Huang
    Yanchun Zhao
    Shulin Zhao
    Microchimica Acta, 2012, 178 : 81 - 88
  • [46] Electrochemical sensing of D-penicillamine on modified glassy carbon electrode by using a nanocomposite of gold nanoparticles and reduced graphene oxide
    Jafari, Marzieh
    Tashkhourian, Javad
    Absalan, Ghodratollah
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (06) : 1253 - 1262
  • [47] Electrochemical DNA biosensor based on a glassy carbon electrode modified with gold nanoparticles and graphene for sensitive determination of Klebsiella pneumoniae carbapenemase
    Pan, Hong-zhi
    Yu, Hong-wei
    Wang, Na
    Zhang, Ze
    Wan, Guang-cai
    Liu, Hao
    Guan, Xue
    Chang, Dong
    JOURNAL OF BIOTECHNOLOGY, 2015, 214 : 133 - 138
  • [48] Electrochemical Determination of Celecoxib on a Graphene Based Carbon Ionic Liquid Electrode Modified with Gold Nanoparticles and Its Application to Pharmaceutical Analysis
    Arkan, Elham
    Karimi, Ziba
    Shamsipur, Mojtaba
    Saber, Reza
    ANALYTICAL SCIENCES, 2013, 29 (08) : 855 - 860
  • [49] Thiol functionalized carbon ceramic electrode modified with multi-walled carbon nanotubes and gold nanoparticles for simultaneous determination of purine derivatives
    Ferrag, Celia
    Noroozifar, Meissam
    Kerman, Kagan
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 110
  • [50] Simultaneous Electrochemical Determination of Dopamine, Uric acid, Tryptophan on Electropolymerized Aminothiazole and Gold nanoparticles Modified Carbon nanotubes Modified Electrode
    Yang, Cheng Yu
    Chen, Shen-Ming
    Palanisamy, Selvakumar
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (04): : 2638 - 2649