Power Quality Improvement Through Backstepping Super-Twisting Control of a DFIG-Based Dual Rotor Wind Turbine System Under Grid Voltage Drop

被引:0
作者
Adil Yahdou
Abdelkadir Belhadj Djilali
Elhadj Bounadja
Zinelaabidine Boudjema
机构
[1] Hassiba Benbouali University of Chlef,Department of Electrical Engineering, Faculty of Technology, Laboratoire Génie Electrique et Energies Renouvelables (LGEER)
来源
Arabian Journal for Science and Engineering | 2024年 / 49卷
关键词
Stator field oriented control; Dual rotor wind turbine; Super-twisting algorithm; Backstepping control; Grid voltage drop scenarios; DFIG;
D O I
暂无
中图分类号
学科分类号
摘要
The stator field-oriented control (SFOC) strategy, utilizing classical proportional-integral (PI) regulators for the doubly fed induction generator (DFIG) within a dual rotor wind turbine (DRWT) system, encounters several significant challenges. These challenges encompass undesirable fluctuations in stator active and reactive powers, the occurrence of a coupling effect in specific scenarios, and a lack of robustness. Moreover, the conventional SFOC demonstrates suboptimal performance in the presence of grid voltage drop scenarios. To address these issues, this study proposes the application of a backstepping super-twisting control (BSTC) strategy. The design of the controller involves integrating a super-twisting algorithm (STA) term into the control law of the classical backstepping control (BC) approach. The MATLAB simulation tests conducted on a 1500 KW DFIG-based DRWT system illustrate the clear superiority of the proposed BSTC over conventional SFOC, BC, and some previously published control methods. In the reference tracking test, the results indicate a significant reduction in the total harmonic distortion (THD) value of the stator current by 57.14% compared to SFOC and by 33.33% compared to BC. Additionally, the BSTC technique, in the same test, also reduces the steady-state error (SSE) for active power by 60% and 28.57% compared to SFOC and BC, respectively. Concerning reactive power, the proposed BSTC strategy decreases SSE by percentages estimated at 56.25% and 12.5%, respectively, compared to SFOC and BC. The computed percentages illustrate the substantial superiority of the suggested controller in enhancing power system characteristics and elevating the quality of energy.
引用
收藏
页码:7145 / 7162
页数:17
相关论文
共 144 条
[81]  
Fujimoto K(undefined)undefined undefined undefined undefined-undefined
[82]  
Sakata N(undefined)undefined undefined undefined undefined-undefined
[83]  
Maruta I(undefined)undefined undefined undefined undefined-undefined
[84]  
Ferguson J(undefined)undefined undefined undefined undefined-undefined
[85]  
Chen C(undefined)undefined undefined undefined undefined-undefined
[86]  
Yu H(undefined)undefined undefined undefined undefined-undefined
[87]  
Hu W(undefined)undefined undefined undefined undefined-undefined
[88]  
Ding F(undefined)undefined undefined undefined undefined-undefined
[89]  
Zhang J(undefined)undefined undefined undefined undefined-undefined
[90]  
Zhang B(undefined)undefined undefined undefined undefined-undefined