Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimum-runs resolution IV design

被引:0
作者
M. Mujeli
S. A. Hussain
M. H. S. Ismail
D. R. A. Biak
M. S. Jami
机构
[1] University Putra Malaysia,Department of Chemical and Environmental Engineering
[2] Modibbo Adama University of Technology,Department of Biotechnology
[3] International Islamic University Malaysia,Department of Biotechnology Engineering
来源
International Journal of Environmental Science and Technology | 2019年 / 16卷
关键词
Electrocoagulation; Minimum-runs resolution IV design; Reclamation; Treated palm oil mill effluent;
D O I
暂无
中图分类号
学科分类号
摘要
The present study aimed at the screening of parameters for electrocoagulation treatment of treated palm oil mill effluent using minimum-runs resolution IV design. The responses examined include: chemical oxygen demand removal (%), total suspended solids removal (%) and turbidity reduction (%), and the varied dependent factors comprise: electrical current density (mA/cm2), time (min), pH, electrolyte concentration (g/L), stirring speed (rpm), electrode spacing (mm) and electrode configuration (monopolar or dipolar). The statistical results revealed that the current density has a significant influence on the treatment performance at two-level interactions with pH, electrode spacing and electrode concentration and at three-level correlations with time and pH. Thus, the most important factors affecting the removal efficiency of the organic compounds were found to be pH, time, electrode spacing, electrolyte concentration and electrode configuration at a P value less than 0.05, respectively, in the descending order of significance. Therefore, the optimized electrocoagulation process could be reached with current density equal to 5 mA/cm2, electrolysis time of 5 min, electrode spacing of 5 mm and using monopolar electrode configuration. This combination provided the maximum ability of the process for chemical oxygen demand (68.84%), total suspended solids (93.27%) and turbidity reduction (92.88%) predictions, with the corresponding experimental values of 69.27, 97.59 and 96.91%, respectively.
引用
收藏
页码:811 / 820
页数:9
相关论文
共 92 条
[1]  
Ahmad AL(2005)Optimization of coagulation-flocculation process for palm oil mill effluent using response surface methodology Environ Sci Technol 39 2828-2834
[2]  
Ismail S(2009)Treatment of textile wastewater by a hybrid electrocoagulation/nanofiltration process J Hazard Mater 168 868-874
[3]  
Bhatia S(2016)Removal of organics from bilge water by batch electrocoagulation process Sep Purif Technol 159 108-115
[4]  
Aouni A(2014)Optimization of the coal flotation procedure using the Plackett–Burman design methodology and kinetic analysis Fuel Process Technol 128 111-118
[5]  
Fersi C(2014)Optimization and kinetic modeling of electrocoagulation treatment of dairy wastewater Desalin Water Treat 3994 1-7
[6]  
Ben Sik Ali M(2015)Optimization of electrocoagulation operating parameters and reactor design for zinc removal : application to industrial Tunisian wastewater Desalin Water Treat 3 495-525
[7]  
Dhahbi M(2011)Electrocoagulation in wastewater treatment Water 38 11-41
[8]  
Aswathy P(2004)Electrochemical technologies in wastewater treatment Sep Purif Technol 61 131-76
[9]  
Gandhimathi R(1993)A catalogue of two-level and three-level fractional factorial designs with small runs Int Stat Rev Revue Internationale de Statistique 19 65-74
[10]  
Ramesh ST(2000)Separation of pollutants from restaurant wastewater by electrocoagulation Sep Purif Technol 9 62-295