CW Operation of a Submillimeter Wave Gyrotron (Gyrotron Fu IV) for High Stability of the Output Frequency

被引:0
|
作者
T. Idehara
K. Yoshida
N. Nishida
I. Ogawa
M. L. Pereyaslavets
T. Tatsukawa
机构
[1] Fukui University,Faculty of Engineering
[2] Kagawa Medical University,Department of Physics, General Education
关键词
Gyrotron; Submillimeter Wave; cw operation;
D O I
暂无
中图分类号
学科分类号
摘要
The first cw operation of our submillimeter wave gyrotron (Gyrotron FU IV) using a 12 T superconducting magnet has been successfully carried out. Output power is more than 20 W at a frequency of 301 GHz in the TE031 resonant cavity mode. Time-resolved frequency measurement s shows that the frequency fluctuation of the gyrotron output is smaller than 2 MHz. This frequency fluctuation is mainly due to the fluctuation in the output voltage of the power supply.
引用
收藏
页码:793 / 801
页数:8
相关论文
共 50 条
  • [1] cw operation of a submillimeter wave gyrotron (Gyrotron FU IV) for high stability of the output frequency
    Idehara, T
    Yoshida, K
    Nishida, N
    Ogawa, I
    Pereyaslavets, ML
    Tatsukawa, T
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1998, 19 (06): : 793 - 801
  • [2] CW operation and amplitude modulation of a submillimeter wave gyrotron (Gyrotron FU-IV)
    Tatsukawa, T
    Shibutani, K
    Yoshida, K
    Nishida, N
    Ogawa, I
    Idehara, T
    ICPP 96 CONTRIBUTED PAPERS - PROCEEDINGS OF THE 1996 INTERNATIONAL CONFERENCE ON PLASMA PHYSICS, VOLS 1 AND 2, 1997, : 1162 - 1165
  • [3] A Frequency Tunable Gyrotron, Gyrotron FU CW IV
    Ogawa, I.
    Idehara, T.
    Chang, T. H.
    Kobayashi, S.
    Saito, T.
    2008 33RD INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES, VOLS 1 AND 2, 2008, : 751 - +
  • [4] Frequency measurement of a submillimeter wave gyrotron output
    Idehara, T
    Yamagishi, Y
    Tatsukawa, T
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1997, 18 (01): : 259 - 272
  • [5] Frequency measurement of a submillimeter wave gyrotron output
    T. Idehara
    Y. Yamagishi
    T. Tatsukawa
    International Journal of Infrared and Millimeter Waves, 1997, 18 : 259 - 272
  • [6] Frequency measurement of a submillimeter wave gyrotron output
    Fukui Univ, Fukui, Japan
    Int J Infrared Millim Waves, 1 (259-272):
  • [7] High quality operation of a submillimeter wave gyrotron
    Ogawa, I
    Idehara, T
    Hoshizuki, H
    Myodo, M
    Nagao, K
    Mitsudo, S
    Hori, T
    IRMMW-THZ2005: THE JOINT 30TH INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES AND 13TH INTERNATIONAL CONFERENCE ON TERAHERTZ ELECTRONICS, VOLS 1 AND 2, 2005, : 433 - 434
  • [8] Submillimetre wave gyrotron (Gyrotron FU IV) for plasma diagnostics
    Shimizu, Y
    Ichikawa, K
    Shibutani, K
    Kurahashi, K
    Tatsukawa, T
    Idehara, T
    Ogawa, I
    Okazaki, Y
    Okamoto, T
    FUSION ENGINEERING AND DESIGN, 1997, 34-35 : 459 - 462
  • [9] Development of a multiple-frequency gyrotron, Gyrotron FU CW GV
    Tatematsu, Yoshinori
    Yamaguchi, Yuusuke
    Ichioka, Ryoichi
    Ogawa, Isamu
    Idehara, Toshitaka
    Saito, Teruo
    2014 39TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2014,
  • [10] Observation of Mode Patterns for High Purity Mode Operation in the Submillimeter Wave Gyrotron FU VA
    T. Idehara
    I. Ogawa
    S. Maeda
    R. Pavlichendko
    S. Mitsudo
    D. Wagner
    M. Thumm
    International Journal of Infrared and Millimeter Waves, 2002, 23 : 973 - 980