Indoor activity size distribution of the short-lived radon progeny

被引:0
作者
Mostafa Yuness
Amer. Mohamed
Hyam Nazmy
Mona Moustafa
Moustafa Abd El-hady
机构
[1] El-Minia University,Physics Department, Faculty of Science
[2] Ural Federal University,undefined
来源
Stochastic Environmental Research and Risk Assessment | 2016年 / 30卷
关键词
Radon progeny; Aerosols; Aerosol activity size distribution; Cascade impactor; Radon progeny deposition;
D O I
暂无
中图分类号
学科分类号
摘要
Activity size distribution of the short-lived radon progeny in indoor air was measured continuously over several weeks. Two different measurement techniques were used: a direct measurement with a low-pressure Berner cascade impactor for attached fraction of 214Pb and 214Bi (≥100 nm) and an indirect determination based on measurement with a wire screen diffusion battery (unattached fraction 0.5–5 nm, 218Po, 214Pb). In parallel, the meteorological parameters like temperature, humidity were registered. Measured activity size distribution of radon progeny can be approximated by a sum of three log-normal distributions modes (nucleation, accumulation and coarse). The greatest activity fraction was adsorbed on aerosol particles in the accumulation size range (100–1000 nm) with activity median aerodynamic diameters (AMADa) and geometric standard deviations (GSDa) values of 250–500 nm, and 1.5–3.5, respectively. The influence of the weather conditions on the activity of the accumulation particles was not significant. In contrast to the results of measurements a small but significant fraction of the radon progeny (average value 5 %) was attached to coarse particles (>1000 nm). This fraction varied between 0 and 10 %. On the other hand, although the amount of unattached activities not more 10 % of the total activity, but is considered to yield about 50 % of the total radiation dose. The mean thermodynamic equivalent diameters of 218Po and 214Pb were determined to be 1.28 and 1.30 nm with relative mean geometric standard deviations of 1.30 and 1.24, respectively. Based on the obtained results of radon progeny size distributions (attached and unattached), the total deposition fractions of the human lung were evaluated by using a lung deposition model.
引用
收藏
页码:167 / 174
页数:7
相关论文
共 59 条
[1]  
Becker KH(1984)Radon daughter activity size distributions Radiat Prot Dosim 7 147-150
[2]  
Reineking A(1992)Use of a graded diffusion battery in measuring the activity size distributions of thoron progeny J Aerosol Sci 23 361-366
[3]  
Scheibel HG(2000)Intercomparison of activity size distribution of thoron progeny and a mixture of radon and thoron progeny J Environ Radioact 51 59-78
[4]  
Porstendorfer J(1994)Particle size of unattached radon progeny in filtered room air Radiat Prot Dosim 56 119-121
[5]  
Cheng YS(2001)Size distribution, equilibrium ratio and unattached fraction of radon decay products under typical indoor domestic conditions Sci Total Environ 272 97-103
[6]  
Su YF(2009)Mitigation of the effective dose of radon decay products through the use of an air cleaner in a dwelling in Okinawa, Japan Appl Radiat Isot 67 1127-1132
[7]  
Newten GJ(2009)Measurement of 220Rn/222Rn progeny deposition velocities on surfaces and their comparison with theoretical models Aerosol Sci 40 1-15
[8]  
Yeh HC(1999)Activity size distribution of short-lived radon progeny in indoor air Radiat Prot Dosim 86 139-143
[9]  
Cheng YS(2014)Deposition pattern of inhaled radon progeny size distribution in human lung J Radiat Res Appl Sci 7 333-337
[10]  
Chen TR(1984)Behaviour of radon daughter products in indoor air Radiat Prot Dosim 7 107-114