Precise, accurate and user-independent blood collection system for dried blood spot sample preparation

被引:0
作者
Ricardo Neto
Andrew Gooley
Michael C. Breadmore
Emily F. Hilder
Florian Lapierre
机构
[1] University of South Australia,Future Industries Institute
[2] ARC Training Centre for Portable Analytical Separation Technologies (ASTech),Australian Centre for Research on Separation Science, School of Natural Sciences
[3] Trajan Scientific and Medical,undefined
[4] University of Tasmania,undefined
来源
Analytical and Bioanalytical Chemistry | 2018年 / 410卷
关键词
Dried blood spot; Microsampling; Glass capillary; Blood;
D O I
暂无
中图分类号
学科分类号
摘要
An accurate and precise 3 μL blood collection and dispensing system is presented for the preparation of dried blood spot (DBS) samples. Using end-to-end glass capillaries in conjugation with pre-punched DBS pads, a blood micro collection system was developed to eliminate the haematocrit dispersion, widely associated with DBS technology, while providing better levels of accuracy and precision during sample preparation. This methodology is compared to traditional micro-volume blood collection systems, such as a pipette and a digitally controlled analytical syringe. Results showed that % of recovery for the capillary methodology was closer to 100% across the three haematocrit (HCT) levels tested and when prepared by two users (98 to 100% for capillaries, 78 to 104% for pipette and 93 to 97% for digital syringe) attesting a higher accuracy. Additionally, by taking advantage of the capillary action mechanism to collect and dispense autonomously the desired volume of blood onto the DBS pad, coefficients of variation between two individuals were significantly lower than with standard methodologies (capillaries—0.05 to 0.77%, pipette—12.71 to 18.53% and digital syringe—0.72 to 1.77%). This alternate aspiration and dispensing methodology could be used by different users without compromising accuracy or precision when handling low volumes of blood during the pre-analytical steps.
引用
收藏
页码:3315 / 3323
页数:8
相关论文
共 81 条
[1]  
Guthrie R(1963)A simple phenylalanine method for detecting phenylketonuria in large populations of newborn infants Pediatrics 32 338-343
[2]  
Susi A(2011)Dried blood spot sampling: practical considerations and recommendation for use with preclinical studies Bioanalysis 3 1099-1107
[3]  
Burnett JE(2011)Analytical methods used in conjunction with dried blood spots Anal Methods 3 1709-1718
[4]  
Tanna S(2013)Current and future use of “ dried blood spot ” analyses in clinical chemistry Clin Chem Lab Med 51 1897-1909
[5]  
Lawson G(2016)Advantages and challenges of dried blood spot analysis by mass spectrometry across the total testing process EJIFCC 27 288-317
[6]  
Lehmann S(2012)What is next for dried blood spots? Bioanalysis 4 2059-2065
[7]  
Delaby C(2014)A method for long term stabilisation of long chain polyunsaturated fatty acids in dried blood spots and its clinical application Prostaglandins Leukot Essent Fat Acids 91 251-260
[8]  
Ducos J(2016)The use of mass spectrometry to analyze dried blood spots Mass Spectrom Rev 35 361-438
[9]  
Hirtz C(2014)Dried blood spots: concepts, present status, and future perspectives in bioanalysis Drug Test Anal 6 399-414
[10]  
Zakaria R(2011)The effect of hematocrit and punch location on assay bias during quantitative bioana lysis of dried blood spot samples Bioanalysis 3 2291-2302