Multidetector CT and Dentascan software: Dosimetric evaluation and technique improvement

被引:10
作者
Fanucci E. [1 ]
Leporace M. [1 ]
Di Costanzo G. [1 ]
Fiaschetti V. [1 ]
Simonetti G. [1 ]
机构
[1] Dipartimento di Diagnostica per Immagini e Radiologia Interventistica, Università degli Studi di Roma Tor Vergata, Policlinico Tor Vergata, I-00133 Roma
关键词
Computed tomography; Dentascan; Dosimetry;
D O I
10.1007/s11547-006-0014-7
中图分类号
学科分类号
摘要
Purpose. The development of new operative techniques in oral and maxillofacial surgery within the last few years has led to an increasing demand for Dentascan examination, also in paediatric patients. It is necessary to modify acquisition parameters to reduce the absorbed dose. The aim of this study was to define a Dentascan protocol in which a reduced X-ray dose could be used. Materials and methods. Dosimeters were applied to the eyes, mouth, parotid glands, thyroid and back of the neck of an anthropomorphic Plexiglas phantom that underwent multidetector computed tomography (MDCT) Dentascan examinations. Both 120kV and 80 kV were used to study the mandibular and maxillary arches. Results. Examinations obtained with the 80 kV protocol showed a ten-fold reduction in the absorbed dose, without affecting image quality. Conclusions. We suggest a Dentascan protocol that reduces the X-ray dose administered to the patient while ensuring the same high diagnostic accuracy.
引用
收藏
页码:130 / 138
页数:8
相关论文
共 15 条
  • [1] Preda L., Rodriguez Y Baena R., Et al., La tomografia computerizzata in implantologia, Radiol Med, 98, pp. 447-453, (1999)
  • [2] Villari N., Fanfani F., Apporto diagnostico della CT nell'implantologia: Utilizzazione di un nuovo programma di ricostruzione Denta-Scan, Radiol Med, 83, pp. 608-614, (1992)
  • [3] Casselman J.W., Deryckere F., Hermans R., Et al., Denta Scan: CT software program used in the anatomic evaluation of the mandible and maxilla in preoperative assessment of dental implants, Ann Radiol, 33, pp. 408-417, (1990)
  • [4] Bianchi S.D., Roccuzzo M., Albrito F., Et al., Dosi assorbite nella radiologia dentale, Radiol Med, 92, pp. 114-121, (1996)
  • [5] Villari N., Stecco A., Zatelli G., Dosimetria nella radiologia odontostomatologica: Confronto tra Tomografia Computerizzata spirale e ortopantomografia, Radiol Med, 97, pp. 378-381, (1999)
  • [6] Lecomber A.R., Yoneyama Y., Lovelock D.J., Et al., Comparison of patient dose from imaging protocols for dental implant planning using conventional radiography and computer tomography, Dentomaxillofac Radiol, 30, pp. 255-259, (2001)
  • [7] Mozzo P., Procacci C., Tacconi A., Et al., A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results, Eur Radiol, 8, pp. 1558-1564, (1998)
  • [8] Kassebaum D.K., Stoller N.E., McDavid W.D., Et al., Adsorbed dose determination for tomographic implant site assessment techniques, Oral Surg Oral Med Oral Pathol, 73, pp. 502-509, (1992)
  • [9] Jurik A.G., Jessen K.A., Hansen J., Image quality and dose in computed tomography, Eur Radiol, 7, pp. 77-81, (1997)
  • [10] Scheck R.J., Coppenrath E.M., Kellner M.W., Et al., Radiation dose and image quality in spiral CT: Multicentre evaluation at 6 institutions, Br J Radiol, 75, pp. 140-150, (2002)