Measurement of 131I activity in thyroid of nuclear medical staff and internal dose assessment in a Polish nuclear medical hospital

被引:0
|
作者
K. Brudecki
A. Kowalska
P. Zagrodzki
A. Szczodry
T. Mroz
P. Janowski
J. W. Mietelski
机构
[1] Polish Academy of Sciences,Institute of Nuclear Physics
[2] Holy Cross Cancer Center,Department of Endocrinology and Nuclear Medicine
[3] Pedagogical University in Cracow,Department of Food Chemistry and Nutrition, Medical College
[4] AGH University of Science and Technology,undefined
[5] Jagiellonian University,undefined
来源
Radiation and Environmental Biophysics | 2017年 / 56卷
关键词
I; Thyroid; Nuclear medicine; Medical personnel; Internal doses;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents results of 131I thyroid activity measurements in 30 members of the nuclear medicine personnel of the Department of Endocrinology and Nuclear Medicine Holy Cross Cancer Centre in Kielce, Poland. A whole-body spectrometer equipped with two semiconductor gamma radiation detectors served as the basic research instrument. In ten out of 30 examined staff members, the determined 131I activity was found to be above the detection limit (DL = 5 Bq of 131I in the thyroid). The measured activities ranged from (5 ± 2) Bq to (217 ± 56) Bq. The highest activities in thyroids were detected for technical and cleaning personnel, whereas the lowest values were recorded for medical doctors. Having measured the activities, an attempt has been made to estimate the corresponding annual effective doses, which were found to range from 0.02 to 0.8 mSv. The highest annual equivalent doses have been found for thyroid, ranging from 0.4 to 15.4 mSv, detected for a cleaner and a technician, respectively. The maximum estimated effective dose corresponds to 32% of the annual background dose in Poland, and to circa 4% of the annual limit for the effective dose due to occupational exposure of 20 mSv per year, which is in compliance with the value recommended by the International Commission on Radiological Protection.
引用
收藏
页码:19 / 26
页数:7
相关论文
共 16 条
  • [1] Measurement of 131I activity in thyroid of nuclear medical staff and internal dose assessment in a Polish nuclear medical hospital
    Brudecki, K.
    Kowalska, A.
    Zagrodzki, P.
    Szczodry, A.
    Mroz, T.
    Janowski, P.
    Mietelski, J. W.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2017, 56 (01) : 19 - 26
  • [2] Measurement of 131I activity in air indoor Polish nuclear medical hospital as a tool for an internal dose assessment
    K. Brudecki
    A. Szczodry
    T. Mróz
    A. Kowalska
    J. W. Mietelski
    Radiation and Environmental Biophysics, 2018, 57 : 77 - 82
  • [3] Measurement of 131I activity in air indoor Polish nuclear medical hospital as a tool for an internal dose assessment
    Brudecki, K.
    Szczodry, A.
    Mroz, T.
    Kowalska, A.
    Mietelski, J. W.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2018, 57 (01) : 77 - 82
  • [4] Thyroid dose assessments due to inhalation of 131I for nuclear medicine workers
    Liu, Gang
    Li, Ye
    Zhang, HanYu
    Zhang, Xue
    Liu, Yin Yin
    Wu, Xiao Qin
    Niu, Li Mei
    Zhang, Rong
    FRONTIERS IN PUBLIC HEALTH, 2022, 10
  • [5] Exposure and contamination assessment of nuclear medical staff during radioiodine therapy for thyroid cancer
    Guillot, S.
    Tylski, P.
    Scheiber, C.
    Bournaud-Salinas, C.
    Bolot, C.
    Harthe, C.
    Jalade, P.
    RADIOPROTECTION, 2016, 51 (03) : 171 - 177
  • [6] Medical activated charcoal tablets as a cheap tool for passive monitoring of gaseous 131I activity in air of nuclear medicine departments
    Mroz, Tomasz
    Brudecki, Kamil
    Mietelski, Jerzy W.
    Bartyzel, Miroslaw
    Misiak, Ryszard
    Kornas, Andrzej
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 318 (01) : 723 - 726
  • [7] Medical activated charcoal tablets as a cheap tool for passive monitoring of gaseous 131I activity in air of nuclear medicine departments
    Tomasz Mróz
    Kamil Brudecki
    Jerzy W. Mietelski
    Mirosław Bartyzel
    Ryszard Misiak
    Andrzej Kornas
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 318 : 723 - 726
  • [8] Internal dosimetry of nuclear medicine workers through the analysis of 131I in aerosols
    Carneiro, Luana Gomes
    de Lucena, Eder Augusto
    Sampaio, Camilla da Silva
    Almeida Dantas, Ana Leticia
    Sousa, Wanderson Oliveira
    Santos, Maristela Souza
    Dantas, Bernardo Maranhao
    APPLIED RADIATION AND ISOTOPES, 2015, 100 : 70 - 74
  • [9] Development of Portable Thyroid Monitoring System for 131I and 133I in Nuclear Emergency
    Jang, Mee
    Kim, Hyun Ki
    Choi, Chang Woon
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 428 - 431
  • [10] Measurement of 131I activity in thyroid using a dual-layer detector
    Liu, Hongming
    Zhao, Chao
    Xu, Xiaohua
    Zhang, Weiyuan
    Yang, Shiyan
    Zhang, Zhiyong
    Chen, Bo
    Zhuo, Weihai
    RADIATION MEASUREMENTS, 2022, 153