Evaluation of hydraulic conductivity of subsoil using electrical resistivity and ground penetrating radar data: example from Southwestern Nigeria

被引:5
作者
Salako A.O. [1 ]
Adepelumi A.A. [1 ]
机构
[1] Department of Geology, Obafemi Awolowo University, Ile-Ife
关键词
Hydraulic conductivity; Porosity; Radar; Resistivity; Seepages;
D O I
10.1186/s40703-016-0018-7
中图分类号
学科分类号
摘要
Groundwater seepage has being linked to the cause of building failures in Erinle area, Ede metropolis, SW Nigeria. A comparative study of the hydraulic conductivity (K) of first two subsoil or subsurface layers underlying the area of investigation was carried out using data acquired from ground penetrating radar (GPR) and electrical resistivity (ER) surveys. Ground penetrating radar (GPR) and electrical survey (ER) were performed along eight traverses over the shallow subsurface. From these a total of eight radar sections and geoelectric sections were developed along an electrode separation of 80 m. The results from the radar section and geoelectric section show that the area under investigated is made up of three stratigraphic layers (laterite topsoil, weathered layer, bedrock). The radar sections show that the second subsurface layer (weathered layer) or subsoil is pervious as compared to the others. The weathered layer shows relatively smooth reflections suggesting high groundwater flow which accounts probably for the groundwater seepage observed. Hydraulic plots and Porosity confirms the pervious nature of the weathered layer as oppose to the other two layers as expressed by high hydraulic conductivity (K) values of 1.0 × 10 −5 –7.4 × 10 −6  m/s and high porosity values of 2.16–5.06 which makes it liable to groundwater seepages. Both the ER and GPR surveys confirmed that the second subsurface layer (weathered layer) is more prone to groundwater seepage especially in traverses (1, 2, 3 and 5) where the relative thickness of the first layer (lateritic topsoil) is less than 5 m and in traverses (4, 6, 7 and 8) having a resistive layer (basement). This study shows the importance of geophysical investigation in detect of groundwater seepage and post-foundation investigations. © 2016, Salako and Adepelumi.
引用
收藏
相关论文
共 29 条
  • [1] Adepelumi A.A., Solanke A.A., Sanusi O.B., Shallangwa A.M., Model tank electrical resistively characterization of LNAPL migration in a clayey-sand formation, Environ Geol, 50, pp. 1221-1233, (2006)
  • [2] Akinniranye O.A., Structural Analysis of the Basement Complex of the Obafemi Awolowo University Campus, (1985)
  • [3] Antonio C., Permeability–porosity relationship: A re-examination of the Kozeny–Carman equation based on a fractal pore-space geometry assumption, Geophys Res Lett, 33, 2, (2006)
  • [4] Archie G.E., The electrical resistivity log as an aid in determining some reservoir characteristics, Transact Am Inst Mineralog Metallurg Eng, 146, pp. 54-62, (1942)
  • [5] Archie G.E., Introduction to petrophyshics of reservoir rocks, AAPG Bulletin, 34, pp. 943-961, (1950)
  • [6] Bakker M.A.J., Maljers D., Weerts H.J.T., Groundpenetrating radar profiing on embanked flodplains, Neth J Geosci, 86, 1, pp. 55-61, (2007)
  • [7] Conyers L.B., Goodman D., Ground Penetrating Radar for Archaeology, (1997)
  • [8] Fajobi A.B., Falade F.A., Adepelumi A.A., Akindulureni J.O., Evaluation of hydraulic conductivity of lateritic soils using integrated approach: southwestern Nigeria case study, Int J Adv Geosci, 3, 1, pp. 1-7, (2015)
  • [9] Johansson S., Dahlin T., Seepage monitoring in an earth embankment dam by repeated resistivity measurements, Eur J Environ Eng Geophys, 1, 3, pp. 229-247, (1996)
  • [10] Knight R.J., The role of ground penetrating radar and geostatistics in reservoir description, The Leading, (1997)