Determination of mercury in air by stripping voltammetry with chromatomembrane preconcentration

被引:0
作者
E. O. Averyaskina
S. S. Ermakov
L. N. Moskvin
机构
[1] St.-Petersburg State University,Department of Chemistry
来源
Journal of Analytical Chemistry | 2006年 / 61卷
关键词
Mercury; Supporting Electrolyte; Mercury Vapor; Maximum Permissible Concentration; Bimodal Pore Size Distribution;
D O I
暂无
中图分类号
学科分类号
摘要
It is shown that mercury can be determined in air by stripping voltammetry at a level of 0.05 μg/m3 (0.005 MPC in the air of working areas) using chromatomembrane preconcentration.
引用
收藏
页码:1100 / 1103
页数:3
相关论文
共 50 条
  • [31] Oligonucleotide Functionalized Microporous Gold Electrode for the Selective and Sensitive Determination of Mercury by Differential Pulse Adsorptive Stripping Voltammetry (DPAdSV)
    Xu Yiwei
    Li Zhihua
    Zhang Wen
    Shi Jiyong
    Zou Xiaobo
    Huang Xiaowei
    Hu Xuetao
    Wang Xin
    [J]. ANALYTICAL LETTERS, 2019, 52 (18) : 2938 - 2950
  • [32] Adsorptive stripping voltammetry of Tartrazine at the hanging mercury drop electrode in soft drinks
    J. J. Berzas Nevado
    J. Rodríguez Flores
    M. J. Villaseñor Llerena
    [J]. Fresenius' Journal of Analytical Chemistry, 1997, 357 : 989 - 994
  • [33] Determination of salmon calcitonin by square wave adsorptive stripping voltammetry
    Osteryoung, JG
    Wikiel, KJ
    [J]. ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) : 65 - 71
  • [34] Determination of selenium(IV) by cathodic stripping voltammetry using a copper-modified mercury-film electrode modified with copper
    N. K. Zaitsev
    E. A. Osipova
    D. M. Fedulov
    E. A. Eremenko
    A. G. Dedov
    [J]. Journal of Analytical Chemistry, 2006, 61 : 77 - 83
  • [35] Highly sensitive determination of mercury using copper enhancer by diamond electrode coupled with sequential injection-anodic stripping voltammetry
    Chaiyo, Sudkate
    Chailapakul, Orawon
    Siangproh, Weena
    [J]. ANALYTICA CHIMICA ACTA, 2014, 852 : 55 - 62
  • [36] Trace mercury determination by differential pulse anodic stripping voltammetry using polythiophene-quinoline/glassy carbon modified electrode
    Yoo, KS
    Woo, SB
    Jyoung, JY
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2003, 24 (01) : 27 - 31
  • [37] Capture Mercury Gold Cartridge-Preconcentration and Determination of Mercury in Particulates of Air Conditioner by Domestic Cool Vapor Atomic Fluorescence Spectrometry
    Lu Jian-Ping
    Wang Li
    Mo Sui-Sui
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (02) : 296 - 298
  • [38] Stripping Voltammetric Determination of Methylmercury in the Presence of Inorganic Mercury
    Korolczuk, Mieczyslaw
    Stepniowska, Anna
    [J]. ELECTROANALYSIS, 2010, 22 (17-18) : 2087 - 2091
  • [39] PERFORMANCE OF PLATINUM-BASED SPHERICAL MERCURY MICROELECTRODES IN CYCLIC VOLTAMMETRY AND STRIPPING ANALYSIS
    BALDO, MA
    DANIELE, S
    CORBETTA, M
    MAZZOCCHIN, GA
    [J]. ELECTROANALYSIS, 1995, 7 (10) : 980 - 986
  • [40] Chelating resin preconcentration and Hg(II) assisted elution followed by differential-pulse anodic stripping voltammetry for the determination of Cd, Cu, and Pb in seawater
    Y.-C. Sun
    Y.-L. Tu
    Jerzy Mierzwa
    [J]. Fresenius' Journal of Analytical Chemistry, 1998, 360 : 550 - 555