Retrofitting parts and assemblies of cogeneration steam turbines for improving their reliability

被引:0
作者
Murmanskii, B.E. [1 ]
Brodov, Y.M. [1 ]
Novoselov, V.B. [1 ]
Sosnovskii, A.Y. [1 ]
Sakhnin, Y.A. [2 ]
机构
[1] Ural Federal University, Yekaterinburg, 620002
[2] Ural Turbine Works, Yekaterinburg, 620017
来源
Thermal Engineering (English translation of Teploenergetika) | 2012年 / 59卷 / 12期
关键词
Cogeneration plants - Steam turbines;
D O I
10.1134/S0040601512120075
中图分类号
学科分类号
摘要
Typical flaws in cogeneration turbines produced by the Ural Turbine Works that revealed them- selves under different conditions of their operation and due to which turbine failures occurred are deter- mined. Generalized results obtained from investigations and approbation of a number of newly developed measures aimed at improving the reliability of the assemblies most susceptible to damages that were imple- mented in retrofitting or repairing cogeneration turbines are presented. © Pleiades Publishing, Inc., 2012.
引用
收藏
页码:930 / 934
页数:4
相关论文
共 15 条
[1]  
Murmanskii B.E., Brodov Y.M., Valamin A.E., Et al., Analysis of indicators characterizing the reliability of cogeneration turbines, Therm. Eng., 1, (2011)
[2]  
Murmanskii B.E., Brodov Y.M., Vasenin S.L., Analysis of typical flaws in steam turbines revealed under field conditions, Tyazh. Mashinostr., 6, pp. 2-5, (2010)
[3]  
Novoselov V.B., Murmanskii B.E., Lebedev V.V., Diagnostics of the turbine unit control and protection system at the present stage, Tyazh. Mashinostr., 2, pp. 69-74, (2012)
[4]  
Modenov S.N., Murmanskii B.E., Brodov Y.M., Et al., Bringing thermal expansions of the cogeneration turbines at the omsk tets-5 cogeneration station to their normal values, Elektr. Stn., 8, pp. 47-51, (2010)
[5]  
Trukhnii A.D., Lomakin B.V., Cogeneration Steam Turbines And Turbine Units, (2002)
[6]  
Steam Turbines and Turbine Units Produced by the Ural Turbine Works, (2010)
[7]  
Rodin V.N., Sharapov A.G., Murmanskii B.E., Et al., Repair of Steam Turbines: A Handbook for Higher Schools, (2005)
[8]  
Terent'ev I.A., Estimating the reliability of the turbines of 300, 800, and 1200mw power units, Elektr. Stn., 6, pp. 2-5, (1998)
[9]  
Shtromberg Yu.Yu., Ponasechkin S.A., Kopsov A.Ya., Damageability of 300mw thermal power units, Elektr. Stn., 3, pp. 16-18, (2000)
[10]  
Novoselov V.B., Retrofitting the control and protection system of the cogeneration steam turbines produced by the ural turbine works by making it an electrohydraulic one, Khim. Tekhnika, 1, pp. 6-10, (2010)