Monte Carlo study of conversion factors for ionization chamber dosimetry in solid slab phantoms for MV photon beams

被引:0
|
作者
Dong-wook Park
Jai-ki Lee
机构
[1] Hanyang University,Department of Nuclear Engineering
[2] Ilsan Paik Hospital,Department of Radiation Oncology
来源
Journal of the Korean Physical Society | 2016年 / 69卷
关键词
Monte Carlo; Solid phantom; RW3; Ion chamber; FC65-G;
D O I
暂无
中图分类号
学科分类号
摘要
For high energy photon beams, solid phantom to water dose conversion factors were calculated by using a Monte Carlo method, and the result were compared with measurements and published data. Based on the absorbed dose to water dosimetry protocol, the conversion factor was theoretically divided into stopping powers ratios, perturbation factors and ratios of absorbed dose to water and that to solid phantom. Data for a Farmer-type chamber and a solid phantom based on polystyrene which is one of the most common material were applied to calculate the conversion factors for 6 MV and 15 MV photon beams. All measurements were conducted after 10 Gy pre-irradiation and thermal equilibrium had been established with solid slabs in a treatment room. The calculated and the measured conversion factors were in good agreement and could be used to confirm the feasibility of the solid phantom as a substitute for water for high energy photon beam.
引用
收藏
页码:647 / 652
页数:5
相关论文
共 50 条
  • [31] Elaboration and experimental validation of a Monte Carlo source model for linac 6 MV photon beams with and without Flattening Filter
    Aboulbanine, Zakaria
    Bahhous, Karim
    RADIATION PHYSICS AND CHEMISTRY, 2022, 201
  • [32] An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets
    Capote, R
    Sánchez-Doblaclo, F
    Leal, A
    Lagares, JI
    Arráns, R
    Hartmann, GH
    MEDICAL PHYSICS, 2004, 31 (09) : 2416 - 2422
  • [33] Direct calibration in megavoltage photon beams using Monte Carlo conversion factor: validation and clinical implications
    Wright, Tracy
    Lye, Jessica E.
    Ramanathan, Ganesan
    Harty, Peter D.
    Oliver, Chris
    Webb, David V.
    Butler, Duncan J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02): : 883 - 904
  • [34] Monte Carlo calculated beam quality correction factors for ionization chambers in carbon ion beams
    Baumann, Kilian
    Derksen, Larissa
    Stolzenberg, Jessica
    Sasse, Pascal
    Zink, Klemens
    Adeberg, Sebastian
    Looe, Hui Khee
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3377 - S3380
  • [35] Total scatter factors of small beams: A multidetector and Monte Carlo study
    Francescon, Paolo
    Cora, Stefania
    Cavedon, Carlo
    MEDICAL PHYSICS, 2008, 35 (02) : 504 - 513
  • [36] On Monte Carlo modeling of megavoltage photon beams: A revisited study on the sensitivity of beam parameters
    Chibani, Omar
    Moftah, Belal
    Ma, C. -M. Charlie
    MEDICAL PHYSICS, 2011, 38 (01) : 188 - 201
  • [37] Monte Carlo calculation of dose rate conversion factors for external exposure to photon emitters in soil
    Clouvas, A
    Xanthos, S
    Antonopoulos-Domis, M
    Silva, J
    HEALTH PHYSICS, 2000, 78 (03): : 295 - 302
  • [38] Monte Carlo study of a free flattening filter to increase surface dose on 12 MV photon beam
    Zeghari, A.
    Saaidi, R.
    El Moursli, R. C.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (02): : 307 - 313
  • [39] Out-of-field beam characteristics of a 6 MV photon beam: Results of a Monte Carlo study
    Atarod, M.
    Shokrani, P.
    Azarnoosh, A.
    APPLIED RADIATION AND ISOTOPES, 2013, 72 : 182 - 194
  • [40] Measurement of 6 MV small field beam profiles - comparison of micro ionization chamber and linear diode array with monte carlo code
    Gul, Attia
    Farrukh, Salman
    Kakakhel, M. Basim
    Ilyas, Nasir
    Naveed, Muhammad
    Haseeb, Abdul
    Mirza, Sikander M.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (04) : 655 - 664