Comparison of range of motion after standard and high-flexion posterior stabilised total knee replacement

被引:0
作者
F. Y. Ng
H. L. Wong
W. P. Yau
K. Y. Chiu
W. M. Tang
机构
[1] The University of Hong Kong,Department of Orthopaedic and Traumatology, Queen Mary Hospital
[2] Tuen Mun Hospital,Department of Orthopaedic and Traumatology
来源
International Orthopaedics | 2008年 / 32卷
关键词
Total Knee Arthroplasty; Knee Flexion; Total Knee Replacement; Patella Resurface; Deep Flexion;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to compare the range of motion after standard version posterior stabilised TKR and high-flexion version TKR in patients receiving bilateral total knee replacement. Thirty-five patients were recruited. The range of motion of the knees was measured clinically with a goniometer in both the pre-operative period and the most recent follow-up. It was found that the pre-operative range of motion was comparable in the two groups. The average post-operative flexion was 105° ± 13° in the standard version group and 106° ± 14° in the high-flexion design group (p = 0.201, paired t-test; beta error = 0.073). A slight loss in flexion was observed in the standard version group (0.5°) as opposed to a slight gain in the high-flexion design group (2°). However, this was not statistically significant (p = 0.251, paired t-test; beta error = 0.105).
引用
收藏
页码:795 / 798
页数:3
相关论文
共 35 条
[1]  
Akagi M(2000)The bisurface total knee replacement: a unique design for flexion J Bone Joint Surg Am 82 1626-1633
[2]  
Nakamura T(2005)In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty J Biomech 38 277-284
[3]  
Matsusue JA(2007)Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery Knee Surg Sports Traumatol Arthrosc 15 350-355
[4]  
Argenson GR(2002)Review article: knee flexion after total knee arthroplasty J Orthop Surg (Hong Kong) 10 194-202
[5]  
Scuderi RD(2005)The early results of high flex total knee arthroplasty: a minimum of 2 years of follow-up J Arthroplasty 20 674-679
[6]  
Komistek SI(2005)Range of motion of standard and high flexion posterior stabilized total knee prostheses. A prospective, randomized study J Bone Joint Surg Am 87 1470-1475
[7]  
Bin TS(2004)Knee kinematics with a high-flexion posterior stabilized total knee prosthesis: an in vitro robotic experimental investigation J Bone Joint Surg Am 86 1721-1729
[8]  
Nam KY(2003)Predicting range of motion after total knee arthroplasty. Clustering, log-linear regression and regression tree analysis J Bone Joint Surg Am 85 1278-1285
[9]  
Chiu TP(1979)Predictive range of motion after total knee replacement Clin Orthop 143 115-119
[10]  
Ng WM(2006)Flexion after total knee replacement. A comparison between the Medial Pivot knee and a posterior stabilised implant Knee 13 371-373