Quantitative risk estimation of CNG station by using fuzzy bayesian networks and consequence modeling

被引:0
作者
Behzad Abbasi Kharajou
Hassan Ahmadi
Masoud Rafiei
Saber Moradi Hanifi
机构
[1] University of Guilan,Department of Urban Planning
[2] University of Guilan,Department of Urban Planning, Faculty of Architecture and Art
[3] Ahvaz Jundishapur University of Medical Sciences,Department of Occupational Health, Faculty of Health
[4] Iran University of Medical Sciences,Department of Occupational Health Engineering, School of Public Health
来源
Scientific Reports | / 14卷
关键词
QRA; FFTA; Bow-tie; Bayesian network; CNG station;
D O I
暂无
中图分类号
学科分类号
摘要
As one of the potential explosions and inflammation, compressed natural gas (CNG) stations in urban areas cause irreparable losses and casualties. Estimating risk assessment in gas stress based on coherent uses can reduce accidents in urban areas. The purpose of the present study was to estimate a small risk estimation at one of the CNG multipurpose stations, LPG, using combined models of the Fuzzy Bayesian Network, Bow-tie Diagram, and consequence modeling. This study was conducted based on the basic and 25 intermediate events. This study formed a seven-person safety team to identify the primary events and build the Bow-tie diagram. Then, because of the lack of a proper database, fuzzy theory was used to determine the probability of significant events. Bayesian networks were drawn based on the Bow-tie model using GeNLe software. Finally, the main events of the two Bow-tie, Bayesian network modeling, and risk estimation were performed with the help of PHAST/SAFETI (V8.22). The geographical information system software was used to zone the explosion effects. The Risk assessment result showed that the social risks and the Bayesian network model are more than Bow-tie, and the Bow-tie diagram is unacceptable. Therefore, using incompatible land uses in the vicinity of the CNG stations gives rise to the effects of accident scenarios in particular residential and administrative land uses, which decision-makers and city managers should consider. Based on the findings of this study, the obtained results can be utilized to implement effective control measures. These measures encompass devising a response plan tailored to address specific emergency conditions and conducting comprehensive training programs for the individuals and residents residing within the study area.
引用
收藏
相关论文
共 149 条
[1]  
Yuan H(2022)System dynamics approach for evaluating the interconnection performance of cross-border transport infrastructure J. Manag. Eng. 38 4022008-390
[2]  
Yang B(2022)Assessment and analysis of potentially explosive areas in distribution stations, generated by alternative fuels such as LPG, CNG and H 2 MATEC Web Conf. 373 00039-216
[3]  
Grecea D(2018)A review of methodologies for safety and hazard management in chemical industries ChemBioEng Rev. 5 372-18
[4]  
Andris A(2017)Identification and assessment of risk factors affecting construction projects HBRC J. 13 202-175
[5]  
Nicola A(2023)Consequence modeling and analysis of Benzene leakage and explosion from a poorly sited gas station in the City of Douala, Cameroon Int. J. Occup. Saf. Health 13 1-523
[6]  
Chikhalikar AS(2018)Bow tie to improve risk management of natural gas pipelines Process Saf. Prog. 37 169-218
[7]  
Jog SH(2012)Risk analysis for oil & gas pipelines: A sustainability assessment approach using fuzzy based bow-tie analysis J. Loss Prev. Process Ind. 25 505-353
[8]  
AbdEl-Karim MSBA(2016)The bowtie method: A review Saf. Sci. 88 211-203
[9]  
MosaElNawawy OA(1965)Fuzzy sets Inform. Control 8 338-123
[10]  
Abdel-Alim AM(1999)Combining probability distributions from experts in risk analysis Risk Anal. 19 187-297