摘要
Cardiac erosion related to transcatheter atrial septal defect closure devices is of increasing concern. Erosion is reported to have occurred with most of currently available occluder devices. Perhaps due to the very large number of implants worldwide, the Amplatzer (St Jude) occluder is associated with the majority of cardiac erosion events reported in the literature. Best current estimates of the incidence of erosion with the St Jude device are between one and three cases per 1000 implants. Most events occur early after implantation and it is rare, although not unheard of, for events to occur after a year following device insertion. It is important that those involved with closure programmes are vigilant for the problem, because device-related erosion is associated with a significant mortality risk. Despite considerable debate, the risk factors (either patient or device) for erosion remain unclear and require further investigation. Currently available data sets have focussed largely on erosion cohorts and are unable to place these cases in appropriate context with non-erosion closure cases. What is certain is that programmes implanting these devices must take care to implant appropriately sized devices and have in place plans to ensure that patients are both well informed and can access help and advice in the event of developing symptoms. © 2015 The authors.
引用
收藏
页码:R73 / R78
页数:5
相关论文
共 19 条
[11]  
Amin Z., Echocardiographic predictors of cardiac erosion after Amplatzer septal occluder placement, Catheterization and Cardiovascular Interventions, 83, pp. 84-92, (2014)
[12]  
Podnar T., Martanovic P., Gavora P., Masura J., Morphological variations of secundum-type atrial septal defects: Feasibility for percutaneous closure using Amplatzer septal occluders, Catheterization and Cardiovascular Interventions, 53, pp. 386-391, (2001)
[13]  
Kitano M., Yazaki S., Sugiyama H., Yamada O., The influence of morphological changes in Amplatzer device on the atrial and aortic walls following transcatheter closure of atrial septal defects, Journal of Interventional Cardiology, 22, pp. 83-91, (2009)
[14]  
Bhaya M., Mutluer F., Mahan E., Mahan L., Hsiung M.C., Yin W.H., Wei J., Tsai S.K., Zhao G.Y., Yin W.H., Live/Real time three-dimensional transesophageal echocardiography in percutaneous closure of atrial septal defects, Echocardiography, 30, pp. 345-353, (2013)
[15]  
Santini F., Morjan M., Onorati F., Morando G., Faggian G., Mazzucco A., Life-threatening isometric-exertion related cardiac perforation 5 years after Amplatzer septal defect closure: Should isometric activity be limited in septal occluder holders?, Annals of Thoracic Surgery, 93, (2012)
[16]  
El-Said H.G., Moore J.W., Erosion by the Amplatzer septal occluder: Experienced operator opinions at odds with manufacturer recommendations?, Catheterization and Cardiovascular Interventions, 73, pp. 925-930, (2009)
[17]  
Wagdi P., Closure of intra-atrial septal communications: Adverse events and lessons learned, Cardiology Research, 2, pp. 7-15, (2011)
[18]  
Hernandez Perez F.J., Fernandez Diaz J.A., Garcia Montero C., Garcia Touchard A., Oteo Dominguez J.F., Dominguez Puente J.R., Goicolea Ruigomez J., Late aortic perforation with a fractured ATRIASEPT II device resulting in life-threatening tamponade, EuroIntervention, 9, (2013)
[19]  
Happel C.M., Laser K.T., Sigler M., Kececioglu D., Sandica E., Haas N.A., Single center experience: Implantation failures, early, and late complications after implantation of a partially biodegradable ASD/PFOdevice (BioStarw, Catheterization and Cardiovascular Interventions, 85, pp. 990-997, (2015)