Late type III endoleak from fabric tears of a zenith stent graft: report of a case

被引:0
|
作者
Hiroshi Banno
Hirofumi Morimae
Tsutomu Ihara
Masayoshi Kobayashi
Kiyohito Yamamoto
Kimihiro Komori
机构
[1] Nagoya University Graduate School of Medicine,Division of Vascular Surgery, Department of Surgery
来源
Surgery Today | 2012年 / 42卷
关键词
Endoleak; Fabric tears; Stent graft; EVAR;
D O I
暂无
中图分类号
学科分类号
摘要
We report a case of late type III B endoleak from a fabric tear in the main body of a Zenith bifurcated stent-graft approximately 19 months after implantation. A follow-up computed tomography (CT) scan showed gradual growth in the size of the aneurysm, but no apparent endoleak was recognized. However, the CT scan had demonstrated a mosaic pattern in the aneurysm sac, which could indicate an endoleak from a fabric tear. The defect was repaired by implantation of body extensions, but the patient died 5 h after the procedure.
引用
收藏
页码:1206 / 1209
页数:3
相关论文
共 50 条
  • [41] A multidisciplinary approach: Case report of an abdominal aortic aneurysm with type IIIA endoleak in the setting of cholangitis
    Ihionkhan, Emmanuel
    Marcucci, Vincent
    Masai, Rachel
    Belitsis, Kenneth
    Khan, Mohammad Nasir
    SAGE OPEN MEDICAL CASE REPORTS, 2023, 11
  • [42] Trans-limb embolization for treatment of Type 2 endoleak post EVAR: Case report
    Dinoto, E.
    Ferlito, F.
    Urso, F.
    Evola, S.
    Bajardi, G.
    Pecoraro, F.
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2021, 85
  • [43] Traumatic brachial artery injury successfully treated with a stent-graft: A case report
    Kawatani, Yohei
    Mochizuki, Takeshi
    Hori, Takaki
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2022, 30 (05) : 586 - 588
  • [44] Stent graft treatment for ruptured pseudoaneurysms of the splanchnic arteries after pancreaticoduodenectomy: a case report
    Nemoto, Masaru
    Koyama, Ken
    Enokido, Midori
    Kudo, Shohei
    Yoshimi, Fuyo
    SURGICAL CASE REPORTS, 2020, 6 (01)
  • [45] Stent graft treatment for ruptured pseudoaneurysms of the splanchnic arteries after pancreaticoduodenectomy: a case report
    Masaru Nemoto
    Ken Koyama
    Midori Enokido
    Shohei Kudo
    Fuyo Yoshimi
    Surgical Case Reports, 6
  • [46] Type 1A endoleak detachable coil embolization after endovascular aneurysm sealing: Case report
    Dinoto, E.
    Ferlito, F.
    Mirabella, D.
    Tortomasi, G.
    Bajardi, G.
    Pecoraro, F.
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2021, 83
  • [47] Successful type II endoleak closure by subclavian-to-carotid artery transposition after stent-graft placement of a distal aortic arch aneurysm
    Zimpfer, D
    Schoder, M
    Fleck, T
    Holzenbein, T
    Cejna, M
    Lammer, J
    Wolner, E
    Grabenwoger, M
    Czerny, M
    THORACIC AND CARDIOVASCULAR SURGEON, 2005, 53 (05) : 322 - 324
  • [48] Placement of an aortomonoiliac stent graft without femorofemoral revascularization in endovascular aneurysm repair: A case report
    Keese M.
    Niedergethmann M.
    Schoenberg S.
    Diehl S.
    Journal of Medical Case Reports, 5 (1)
  • [49] Successful treatment of an aorto-ileal-conduit fistula with an endovascular stent graft: Report of a case
    Ishibashi, Hiroyuki
    Ohta, Takashi
    Sugimoto, Ikuo
    Kawanishi, Jun
    Yamada, Tetsuya
    Ishiguchi, Tsuneo
    Io, Akinori
    SURGERY TODAY, 2007, 37 (04) : 305 - 307
  • [50] Successful Treatment of an Aorto-Ileal-Conduit Fistula with an Endovascular Stent Graft: Report of a Case
    Hiroyuki Ishibashi
    Takashi Ohta
    Ikuo Sugimoto
    Jun Kawanishi
    Tetsuya Yamada
    Tsuneo Ishiguchi
    Akinori Io
    Surgery Today, 2007, 37 : 305 - 307