Application of a Plasmonic Biosensor for Detection of Human-Liver Tissues

被引:0
作者
V. A. Popescu
机构
[1] University Politehnica of Bucharest,Department of Physics
来源
Plasmonics | 2018年 / 13卷
关键词
Sensors; Surface plasmon resonance; Finite element method;
D O I
暂无
中图分类号
学科分类号
摘要
A recently published plasmonic biosensor based on birefringent solid-core microstructured optical fiber is applied for detection of five types of human-liver tissues (normal N, metastatic MET, non-cancerous metastatic (NMET), hepatocellular carcinoma (HCC), and non-cancerous hepatocellular carcinoma (NHCC)). The birefringent behavior is obtained by removing five central air holes of a two-ring hexagonal lattice of holes in a gold covered silica fiber with the liver layer surrounding the fiber. The loss spectra show two resonant peaks corresponding to the phase matching points. To distinguish between normal and malignant liver tissues, we compare the relevant parameter for the type I and II core modes. Thus, for a decrease of the real part of the refractive index from 1.373431 (human-liver N) to 1.354602 (human-liver MET), the resonance spectral width δλ0.5 is increased from 44.3 to 54.2 nm for the core mode II. In addition, the amplitude sensitivity SA is decreased from 158.6 to 88.4 RIU−1 for the same core mode. The advantages of another recently proposed plasmonic sensor based on a Bragg fiber are the larger values of the transmission loss, maximum value of the amplitude sensitivity, figure of merit, power fraction in a normal liver layer, and power fraction in the gold layer as compared with that for a microstructured fiber when applied for detection of a normal liver tissue. Another advantage of the Bragg fiber is related to the smaller value of the difference between maximal amplitude sensitivity and resonant wavelengths.
引用
收藏
页码:575 / 582
页数:7
相关论文
共 46 条
  • [1] Giannios P(2016)Visible to near-infrared refractive properties of freshly-excised human-liver tissues: marking hepatic malignancies Sci Rep 6 27910-3046
  • [2] Toutouzas KG(2016)In situ targeting TEM8 via immune response and polypeptide recognition by wavelengthmodulated surface plasmon resonance biosensor Sci Rep 6 20006-1070
  • [3] Matiatou M(2012)Power absorption efficiency of a new microstructured plasmon optical fiber J Opt Soc Am B 29 3039-1189
  • [4] Stasinos K(2014)Strong power absorption in a new microstructured holey fiber-based plasmonic sensor J. Opt. Soc. Am. B 31 1062-326
  • [5] Konstadoulakis MM(2016)Simulation of the sensing performance of a plasmonic biosensor based on birefringent solid-core microstructured optical fiber Plasmonics 11 1183-1491
  • [6] Zografos GC(2016)Sensing performance of the Bragg fiber-based plasmonic sensors with four layers Plasmonics 274 320-1565
  • [7] Moutzouris K(2007)Influence of dopants on the performance of a fiber optic surface plasmon resonance sensor Opt Commun 281 1486-1177
  • [8] Wang Y(2008)Surface plasmon resonance based tapered fiber optic sensor with different taper profiles Opt Commun 87 1564-507
  • [9] Luo Z(2000)Sellmeier parameters for ZnGaP J Appl Phys 71 085416-undefined
  • [10] Liu K(2005) and GaP Phys Rev B 37 1175-undefined