New approach to calibrating conductivity meters in the low conductivity range

被引:0
作者
Petra Spitzer
Bruno Rossi
Yves Gaignet
Stéphane Mabic
Uwe Sudmeier
机构
[1] Metrology in Chemistry,Physikalisch
[2] Lab Water Division,Technische Bundesanstalt
[3] Millipore,undefined
来源
Accreditation and Quality Assurance | 2005年 / 10卷
关键词
Electrolytic conductivity; High purity water; Calibration; Primary methods; Metrology in chemistry;
D O I
暂无
中图分类号
学科分类号
摘要
There is currently a major issue with the calibration of conductivity meters used for high purity water: the lack of availability of a reference material or reference methods for low conductivity ranges (conductivity below 1 μS cm−1 at 25.0 °C, resistivity >1 MΩ cm at 25.0 °C). This paper describes the current status of conductivity measurements in high purity water. A new and improved approach, currently being investigated, should allow us to make the calibration of conductivity meters used for low conductivity ranges traceable to the SI.
引用
收藏
页码:78 / 81
页数:3
相关论文
共 29 条
  • [21] Design of a new TDR probe to measure water content and electrical conductivity in highly saline soils
    Tan, Xiao
    Wu, Jingwei
    Huang, Jiesheng
    Wu, Mousong
    Zeng, Wenzhi
    JOURNAL OF SOILS AND SEDIMENTS, 2018, 18 (03) : 1087 - 1099
  • [22] Electrical Conductivity of Lithium, Sodium, Potassium, and Quaternary Ammonium Salts in Water, Acetonitrile, Methanol, and Ethanol over a Wide Concentration Range
    Dorn, Marvin
    Kareth, Sabine
    Weidner, Eckhard
    Petermann, Marcus
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2024, 69 (04) : 1493 - 1502
  • [23] A new approach of coupled long-range forecasts for streamflow and groundwater level
    Robertson, David E.
    Fu, Guobin
    Barron, Olga
    Hodgson, Geoff
    Schepen, Andrew
    JOURNAL OF HYDROLOGY, 2024, 631
  • [24] A study of the importance of the cell geometry in non-Faradaic systems. A new definition of the cell constant for conductivity measurement
    Bataller, Roman
    Manuel Gandia, Jose
    Garcia-Breijo, Eduardo
    Alcaniz, Miguel
    Soto, Juan
    ELECTROCHIMICA ACTA, 2015, 153 : 263 - 272
  • [25] New Approach for Low-Cost TLS Target Measurement
    Lichti, D. D.
    Glennie, C. L.
    Jahraus, A.
    Hartzell, P.
    JOURNAL OF SURVEYING ENGINEERING, 2019, 145 (03)
  • [26] Performance Evaluation of TEROS 10 Sensor in Diverse Substrates and Soils of Different Electrical Conductivity Using Low-Cost Microcontroller Settings
    Fragkos, Athanasios
    Loukatos, Dimitrios
    Kargas, Georgios
    Arvanitis, Konstantinos G.
    LAND, 2025, 14 (02)
  • [27] A new calibration setup for lock-in amplifiers in the low frequency range and its validation in a bilateral comparison
    Cultrera, Alessandro
    Corminboeuf, David
    D'Elia, Vincenzo
    Tran, Ngoc Thanh Mai
    Callegaro, Luca
    Ortolano, Massimo
    METROLOGIA, 2021, 58 (02)
  • [28] Multicell Model of La3Ga5GeO14 Crystal: A New Approach to the Description of the Short-Range Order of Atoms
    Dudka, A. P.
    CRYSTALLOGRAPHY REPORTS, 2017, 62 (03) : 374 - 381
  • [29] A New Approach for Estimating Soil Salinity Using A Low-Cost Soil Sensor In Situ: A Case Study in Saline Regions of China's East Coast
    Wang, Jianjun
    Sun, Quan
    Shang, Jiali
    Zhang, Jiahua
    Wu, Fei
    Zhou, Guisheng
    Dai, Qigen
    REMOTE SENSING, 2020, 12 (02)