New approach to calibrating conductivity meters in the low conductivity range

被引:0
|
作者
Petra Spitzer
Bruno Rossi
Yves Gaignet
Stéphane Mabic
Uwe Sudmeier
机构
[1] Metrology in Chemistry,Physikalisch
[2] Lab Water Division,Technische Bundesanstalt
[3] Millipore,undefined
来源
Accreditation and Quality Assurance | 2005年 / 10卷
关键词
Electrolytic conductivity; High purity water; Calibration; Primary methods; Metrology in chemistry;
D O I
暂无
中图分类号
学科分类号
摘要
There is currently a major issue with the calibration of conductivity meters used for high purity water: the lack of availability of a reference material or reference methods for low conductivity ranges (conductivity below 1 μS cm−1 at 25.0 °C, resistivity >1 MΩ cm at 25.0 °C). This paper describes the current status of conductivity measurements in high purity water. A new and improved approach, currently being investigated, should allow us to make the calibration of conductivity meters used for low conductivity ranges traceable to the SI.
引用
收藏
页码:78 / 81
页数:3
相关论文
共 29 条
  • [1] New approach to calibrating conductivity meters in the low conductivity range
    Spitzer, P
    Rossi, B
    Gaignet, Y
    Mabic, S
    Sudmeier, U
    ACCREDITATION AND QUALITY ASSURANCE, 2005, 10 (03) : 78 - 81
  • [2] The influence of grain size on the performance of conductivity concentration meters
    van Wijk, J. M.
    Blok, B. W. G.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 45 : 384 - 390
  • [3] LOW ELECTROLYTIC CONDUCTIVITY STANDARDS
    WU, YC
    BEREZANSKY, PA
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1995, 100 (05) : 521 - 527
  • [4] A New Approach in Determining Limiting Molar Conductivity value for Liquid Electrolyte
    Hanibah, Hussein
    Ahmad, Azizan
    Hassan, Nur Hasyareeda
    ELECTROCHIMICA ACTA, 2014, 147 : 758 - 764
  • [5] REFERENCE MATERIALS FOR CALIBRATING PROBES USED FOR MEASURING THERMAL-CONDUCTIVITY OF FROZEN FOODS
    TONG, CH
    SHEEN, S
    SHAH, KK
    HUANG, VT
    LUND, DB
    JOURNAL OF FOOD SCIENCE, 1993, 58 (01) : 186 - &
  • [6] A new approach for calibrating safety performance functions
    Farid, Ahmed
    Abdel-Aty, Mohamed
    Lee, Jaeyoung
    ACCIDENT ANALYSIS AND PREVENTION, 2018, 119 : 188 - 194
  • [7] Calibrating Power Meters in the 140-220-GHz Frequency Range Using an Absolute-Power Reference Calorimeter
    Tojima, Yuya
    Kinoshita, Moto
    Iida, Hitoshi
    Fujii, Katsumi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [8] Calibrating K and Alpha in Gy’s Formula: A New Approach
    Richard Minnitt
    Mathematical Geosciences, 2016, 48 : 211 - 232
  • [9] Calibrating K and Alpha in Gy's Formula: A New Approach
    Minnitt, Richard
    MATHEMATICAL GEOSCIENCES, 2016, 48 (02) : 211 - 232
  • [10] A new TDR probe for measurements of soil solution electrical conductivity
    Moret-Fernandez, D.
    Vicente, J.
    Araguees, R.
    Pena, C.
    Lopez, M. V.
    JOURNAL OF HYDROLOGY, 2012, 448 : 73 - 79