Validation of a photoplethysmography device for detection of obstructive sleep apnea in the perioperative setting

被引:0
|
作者
Philipp Faßbender
Ali Haddad
Silja Bürgener
Jürgen Peters
机构
[1] Universität Duisburg-Essen and Universitätsklinikum Essen,Klinik für Anästhesiologie und Intensivmedizin
来源
Journal of Clinical Monitoring and Computing | 2019年 / 33卷
关键词
Anesthesia; Photoplethysmography; Sleep apnea; Screening; Perioperative safety;
D O I
暂无
中图分类号
学科分类号
摘要
Obstructive sleep apnea (OSA) is a risk factor for perioperative complications, but many OSA patients present undiagnosed. While polysomnography (PSG) is the “gold standard” for diagnosis, its application is technology-intense, time-consuming, expensive, and requires specialists, often delaying surgery. Thus, miniaturized devices were developed for OSA screening aimed at ruling out major OSA while measuring a lesser number of biological signals. We evaluated the accuracy of a photoplethysmography (PPG)-based device for OSA detection. 48 patients with established or strongly suspected (STOP-Questionnaire) OSA scheduled for surgery underwent in their preoperative nights parallel recordings by PPG and a classic polygraphy (PG) devices (SomnoLab2®). We compared the diagnostic accuracy of the PPG in diagnosing mild [Apnea-/Hypopnea-Index (AHI) 5–14 events/h] and moderate-to-severe OSA (AHI > 15). PPG and PG-derived AHI correlated significantly (r = 0.85, p < 0.0001) and high area under curve (AUC) in receiver operator characteristics (ROC) values were seen for both AHI thresholds (0.93 and 0.95, respectively). For an AHI > 5, sensitivity was 100%, specificity 44%, positive predictive value (PPV) 62%, negative predictive value (NPV) 100%, likelihood ratio (LHR) 1.79, and Cohen κ was 0.43. For an AHI > 15, sensitivity was 92%, specificity 77%, PPV 60%, NPV 96%, LHR 4.04, and Cohen κ was 0.59. In a typical perioperative cohort of confirmed and suspected OSA patients, PPG reliably detected OSA patients while showing some false-positive results. Such devices are helpful for preoperative OSA screening.
引用
收藏
页码:341 / 345
页数:4
相关论文
共 50 条
  • [1] Validation of a photoplethysmography device for detection of obstructive sleep apnea in the perioperative setting
    Fassbender, Philipp
    Haddad, Ali
    Buergener, Silja
    Peters, Juergen
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2019, 33 (02) : 341 - 345
  • [2] Central Sleep Apnea Detection by Means of Finger Photoplethysmography
    Massie, Frederik
    Vits, Steven
    Khachatryan, Ani
    Van Pee, Bart
    Verbraecken, Johan
    Bergmann, Jeroen
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2023, 11 : 126 - 136
  • [3] Perioperative Management of Obstructive Sleep Apnea
    Kaw R.
    Gay P.C.
    Current Sleep Medicine Reports, 2015, 1 (4) : 251 - 256
  • [4] Perioperative Management of Obstructive Sleep Apnea
    Adesanya, Adebola O.
    Lee, Won
    Greilich, Nancy B.
    Joshi, Girish P.
    CHEST, 2010, 138 (06) : 1489 - 1498
  • [5] Perioperative Management of Obstructive Sleep Apnea
    Abdullah H.R.
    Chung F.
    Current Anesthesiology Reports, 2014, 4 (1) : 19 - 27
  • [6] Single channel photoplethysmography-based obstructive sleep apnea detection and arrhythmia classification
    Chen, Xiang
    Huang, Jiahao
    Luo, Feifei
    Gao, Shang
    Xi, Min
    Li, Jin
    TECHNOLOGY AND HEALTH CARE, 2022, 30 (02) : 399 - 411
  • [7] Obstructive Sleep Apnea and the Adult Perioperative Patient
    Spence, Dennis L.
    Han, Tony
    McGuire, Jason
    Couture, Darren
    JOURNAL OF PERIANESTHESIA NURSING, 2015, 30 (06) : 528 - 545
  • [8] Perioperative management of patients with obstructive sleep apnea
    Zausig, Y. A.
    Arzt, M.
    PNEUMOLOGE, 2014, 11 (05): : 386 - 392
  • [9] Perioperative Care of Patients with Obstructive Sleep Apnea
    Roop Kaw
    Bhargavi Gali
    Nancy A. Collop
    Current Treatment Options in Neurology, 2011, 13 : 496 - 507
  • [10] Perioperative Complications in Obstructive Sleep Apnea Patients
    Auckley D.
    Current Sleep Medicine Reports, 2016, 2 (2) : 87 - 98