Cardiac arrhythmia catheter ablation procedures guided by x-ray imaging: N-acetylcysteine protection against radiation-induced cellular damage (CARAPACE study): study design

被引:0
作者
Valentina Catto
Giulia Stronati
Benedetta Porro
Susanna Fiorelli
Veronica Ricci
Chiara Vavassori
Eleonora Russo
Federico Guerra
Alessio Gasperetti
Valentina Ribatti
Rita Sicuso
Antonio Dello Russo
Fabrizio Veglia
Claudio Tondo
Viviana Cavalca
Gualtiero I. Colombo
Elena Tremoli
Michela Casella
机构
[1] Centro Cardiologico Monzino IRCCS,Heart Rhythm Center
[2] Marche Polytechnic University,Cardiology and Arrhythmology Clinic
[3] University Hospital “Ospedali Riuniti”,Unit of Metabolomics and Cellular Biochemistry of Atherothrombosis
[4] Centro Cardiologico Monzino IRCCS,Unit of Immunology and Functional Genomics
[5] Centro Cardiologico Monzino IRCCS,Department of Cardiovascular Disease, Division of Cardiac Surgery
[6] Casa Sollievo della Sofferenza IRCCS,Unit of Biostatistics
[7] Centro Cardiologico Monzino IRCCS,Department of Clinical Sciences and Community Health
[8] University of Milan,Department of Clinical, Special and Dental Sciences
[9] Centro Cardiologico Monzino IRCCS,undefined
[10] Marche Polytechnic University,undefined
[11] University Hospital “Ospedali Riuniti”,undefined
来源
Journal of Interventional Cardiac Electrophysiology | 2021年 / 61卷
关键词
Catheter ablation; Radiological risk; Ionizing radiation; Fluoroscopy; Oxidative stress; DNA damage;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:577 / 582
页数:5
相关论文
共 293 条
  • [1] Kirchhof P(2016)2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS Europace 18 1609-1678
  • [2] Benussi S(2019)2019 ESC Guidelines for the management of patients with supraventricular tachycardia the task force for the management of patients with supraventricular tachycardia of the European Society of Cardiology (ESC) Eur Heart J 41 655-720
  • [3] Kotecha D(2014)Practical ways to reduce radiation dose for patients and staff during device implantations and electrophysiological procedures Europace 16 946-964
  • [4] Ahlsson A(2018)2018 ACC/HRS/NASCI/SCAI/SCCT expert consensus document on optimal use of ionizing radiation in cardiovascular imaging—best practices for safety and effectiveness, part 2: radiological equipment operation, dose-sparing methodologies, patient and medical personnel protection: a report of the American College of Cardiology Task Force on expert consensus decision pathways J Am Coll Cardiol 71 2829-2855
  • [5] Atar D(2016)Near zerO fluoroscopic exPosure during catheter ablAtion of supRavenTricular arrhYthmias: the NO-PARTY multicentre randomized trial Europace 18 1565-1572
  • [6] Casadei B(2009)Genetic polymorphisms in XRCC1, OGG1, APE1 and XRCC3 DNA repair genes, ionizing radiation exposure and chromosomal DNA damage in interventional cardiologists Mutat Res Fundam Mol Mech Mutagen 666 57-63
  • [7] Castella M(2015)The isoprostanes--25 years later Biochim Biophys Acta 1851 433-445
  • [8] Diener HC(1999)Ratio of reduced to oxidized glutathione as indicator of oxidative stress status and DNA damage Methods Enzymol 299 267-276
  • [9] Heidbuchel H(2004)Oxidative DNA damage and disease: induction, repair and significance Mutat Res Rev Mutat Res 567 1-61
  • [10] Hendriks J(2018)Does fluoroscopy induce DNA oxidative damage in patients undergoing catheter ablation? Antioxid Redox Signal 28 1137-1143