Preoperative laxity in osteoarthritis patients undergoing total knee arthroplasty

被引:0
作者
Yoshinori Ishii
Hideo Noguchi
Yoshikazu Matsuda
Hiroshi Kiga
Mitsuhiro Takeda
Shin-ichi Toyabe
机构
[1] Ishii Orthopaedic and Rehabilitation Clinic,Department of Medical Informatics
[2] Niigata University Medical and Dental Hospital,undefined
来源
International Orthopaedics | 2009年 / 33卷
关键词
Total Knee Arthroplasty; Medial Collateral Ligament; Joint Space Narrowing; Soft Tissue Release; Stress Radiograph;
D O I
暂无
中图分类号
学科分类号
摘要
A preoperative quantitative evaluation of soft tissues is helpful for planning total knee arthroplasty, in addition to the conventional clinical examinations involved in moving the knee manually. We evaluated preoperative coronal laxity with osteoarthritis in patients undergoing total knee arthroplasty by applying a force of 150 N with an arthrometer. We examined a consecutive series of 120 knees in 102 patients. The median laxity was 0° in abduction and 8° in adduction. The femorotibial angle on non-weight-bearing standard anteroposterior radiographs was 180° and correlated with both abduction (r = −0.244, p = 0.007) and adduction (r = 0.205, p = 0.025) laxity. The results of a regression analysis suggested that the femorotibial angle is helpful for estimating both laxities. Considering the many reports on how to obtain well-balanced soft tissues, stress radiographs might help to improve the preoperative planning for gaining the optimal laxity deemed appropriate by surgeons.
引用
收藏
页码:105 / 109
页数:4
相关论文
共 99 条
[1]  
Bolognesi M(2005)Computer navigation versus standard instrumentation for TKA: a single-surgeon experience Clin Orthop Relat Res 440 162-169
[2]  
Hofmann A(1999)Substantial superiority of semiflexed (MTP) views in knee osteoarthritis: a comparative radiographic study, without fluoroscopy, of standing extended, semiflexed (MTP), and Schuss views J Rheumatol 26 2664-2674
[3]  
Buckland-Wright JC(2004)Influence of the quality of tibial plateau alignment on the reproducibility of computer joint space measurement from Lyon Schuss radiographic views of the knee in patients with knee osteoarthritis Osteoarth Cartil 12 765-770
[4]  
Wolfe F(2001)Early failures in total knee arthroplasty Clin Orthop Relat Res 392 315-318
[5]  
Ward RJ(2002)Changes in human knee ligament stiffness secondary to osteoarthritis J Orthop Res 20 204-207
[6]  
Flowers N(1998)Wear patterns on tibial plateaus from varus and valgus osteoarthritic knees Clin Orthop Relat Res 352 149-158
[7]  
Hayne C(1983)Static and dynamic loading patterns in knee joints with deformities J Bone Joint Surg Am 65 247-259
[8]  
Conrozier T(2002)Effect of selective lateral ligament release on stability in knee arthroplasty Clin Orthop Relat Res 404 24-31
[9]  
Favret H(1957)Radiological assessment of osteoarthritis Ann Rheum Dis 16 494-501
[10]  
Mathieu P(1981)The role of joint load in knee stability J Bone Joint Surg Am 63 570-585