Is contrast-enhanced cardiac magnetic resonance imaging at 3 T superior to 1.5 T for detection of coronary artery disease?

被引:0
|
作者
Thomas Walcher
Katharina Ikuye
Wolfgang Rottbauer
Jochen Wöhrle
Peter Bernhardt
机构
[1] University of Ulm,Department of Internal Medicine II
关键词
3 Tesla; Cardiac magnetic resonance imaging; Coronary disease; Adenosine perfusion;
D O I
暂无
中图分类号
学科分类号
摘要
The aim is to compare a compiled clinical routine cardiac magnetic resonance (CMR) imaging protocol performed at both 1.5 and 3 T in patients with suspected coronary artery disease (CAD) undergoing coronary X-ray angiography. CMR including adenosine perfusion and late gadolinium enhancement (LGE) at 1.5 T has been established for noninvasive detection of relevant CAD. However, little is known about the potential advantages of 3 T to detect CAD. Fifty-two evaluable patients (62.3 ± 10.2 years) were included into the study. All patients were scanned at both 1.5 and 3 T including adenosine stress and rest perfusion, and LGE imaging. CMR images were analyzed by two blinded readers in consensus. X-Ray angiography served as the reference method. A significant CAD was diagnosed by quantitative coronary analysis. Diagnostic accuracy of the combined analysis of perfusion and LGE imaging yielded better values at 1.5 and 3 T than the analysis of perfusion images alone. Specificity and sensitivity at 3 T was superior to 1.5 T in detecting coronary stenoses ≥50 % (90 vs. 75 % and 84.4 vs. 75 %) and ≥70 % (88 vs. 80 % and 96.3 vs. 88.9 %). This study showed that CMR at 3 T in a routine clinical setting is superior to 1.5 T in detection of significant CAD. 3 T might become the preferred CMR field strength for evaluation of CAD in clinical practice.
引用
收藏
页码:355 / 361
页数:6
相关论文
共 50 条
  • [21] 2008 Usefulness of cardiac troponin T for prediction of microvascular obstruction as determined by contrast-enhanced cardiac magnetic resonance imaging
    Mirja Neizel
    Simon Futterer
    Lars Reinhardt
    Evangelos Giannitsis
    Hugo A Katus
    Henning Steen
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [22] Adenosine-stress magnetic resonance perfusion for detection of coronary artery stenosis at 3 T is not inferior to 1.5 T
    Peter Bernhardt
    Jochen Spieß
    Robert Gradinger
    Vinzenz Hombach
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [23] Detection of myocardial scar by contrast-enhanced cardiac magnetic resonance imaging in patients with troponin-positive chest pain and minimal angiographic coronary artery disease
    Christiansen, JP
    Edwards, C
    Sinclair, T
    Armstrong, G
    Scott, A
    Patel, H
    Hart, H
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (06): : 768 - 771
  • [24] Cardiac sarcoidosis:: Diagnosis by contrast-enhanced magnetic resonance imaging
    Garcia-Gallego, Francisco
    Bret-Zurita, Montserrat
    Garcia-Quero, Cristina
    Cuesta-Lopez, Emilio
    REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (07): : 784 - 786
  • [25] Dynamic contrast-enhanced 3-T magnetic resonance imaging: a method for quantifying disease activity in early polyarthritis
    Navalho, Marcio
    Resende, Catarina
    Rodrigues, Ana Maria
    Gaspar, Augusto
    Fonseca, Joao Eurico
    Canhao, Helena
    Campos, Jorge
    SKELETAL RADIOLOGY, 2012, 41 (01) : 51 - 59
  • [26] Dynamic contrast-enhanced 3-T magnetic resonance imaging: a method for quantifying disease activity in early polyarthritis
    Márcio Navalho
    Catarina Resende
    Ana Maria Rodrigues
    Augusto Gaspar
    João Eurico Fonseca
    Helena Canhão
    Jorge Campos
    Skeletal Radiology, 2012, 41 : 51 - 59
  • [27] Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3 T Using Interleaved Echo Planar Imaging
    Bhat, Himanshu
    Yang, Qi
    Zuehlsdorff, Sven
    Li, Kuncheng
    Li, Debiao
    INVESTIGATIVE RADIOLOGY, 2010, 45 (08) : 458 - 464
  • [28] Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3 T With Radial EPI
    Bhat, Himanshu
    Yang, Qi
    Zuehlsdorff, Sven
    Li, Kuncheng
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 82 - 91
  • [29] Automated coronary artery tracking in contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0T
    D Dey
    A Schuhbaeck
    Q Yang
    Z Fan
    G Germano
    S Achenbach
    D Li
    P Slomka
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [30] Is cardiac magnetic resonance adenosine perfusion at 3 tesla superior to 1.5 tesla for detection of relevant coronary artery stenosis?
    Bernhardt, P.
    Gradinger, R.
    Walcher, T.
    Rottbauer, W.
    EUROPEAN HEART JOURNAL, 2011, 32 : 365 - 366